Chapter 2: Server Installation
2-5
Installing the Chassis Rails
Position the fixed chassis rail sections you just removed along the side of
the 5013G-6/5013G-i chassis making sure the five screw holes line up.
Note that these two rails are left/right specific. Screw the rail securely to
the side of the chassis (see Figure 2-2). Repeat this procedure for the
other rail on the other side of the chassis. You will also need to attach the
rail brackets when installing into a telco rack.
Locking Tabs:
As you have seen, both chassis rails have a locking tab,
which serves two functions. The first is to lock the server into place
when installed and pushed fully into the rack, which is its normal position.
Secondly, these tabs also lock the server in place when fully extended
from the rack. This prevents the server from coming completely out of
the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
Installing the Rack Rails
Determine where you want to place the SuperServer 5013G-6/5013G-i in
the rack (see Rack and Server Precautions in Section 2-3). Position the
fixed rack rail/sliding rail guide assemblies at the desired location in the
rack, keeping the sliding rail guide facing the inside of the rack. Screw the
Содержание SUPERSERVER 5013G-6
Страница 1: ...SUPER SUPERSERVER 5013G 6 5013G i USER SMANUAL Revision 1 0b...
Страница 5: ...v Preface Notes...
Страница 10: ...SUPERSERVER 5013G 6 5013G i User s Manual x Notes...
Страница 18: ...SUPERSERVER 5013G 6 5013G i Manual 1 8 Notes...
Страница 30: ...2 12 SUPERSERVER 5013G 6 5013G i Manual Notes...
Страница 34: ...SUPERSERVER 5012G 6 5012G E Manual 3 4 Notes...
Страница 62: ...5 24 SUPERSERVER 5013G 6 5013G i Manual Notes...
Страница 72: ...6 10 SUPERSERVER 5013G 6 5013G i Manual Notes...
Страница 108: ...B 6 SUPERSERVER 5013G 6 5013G i Manual Notes...