6-10
FatTwin F628G3-FT+/FTPT+ User's Manual
6-8 Removing and Installing the Backplane
The F424AG chassis backplane is located behind the hard drives in each
serverboard node. Although backplane failure rarely occurs, in the event of a
backplane failure, follow the instructions below.
Removing the Backplane
Removing the Backplane from the Node
1. Remove the power cord from the rear of the node as described in Section
6-3. Remove the node from the chassis as described in Section 6-4. Place
the node on a fl at, stable surface and remove the node cover as described in
Section 6-7.
2. Lift the mylar air shroud off the top of the serverboard and remove it from the
node.
3. Remove the two screws securing the backplane to the node.
Figure 6-8: Removing the Screws from the Backplane
4. Lift the backplane up and out of the node.
Figure 6-9: Removing the Backplane from the Node