Chapter 6: Advanced Chassis Setup
6-23
6-15 Replacing System Fans
Each node supports rear exhaust fans that provide cooling for the node. These fans
circulate air through the node as a means of lowering the internal temperature. In
the unlikely event of a fan failure, the F424AG fans are easily removed from the
rear of the node without tools.
Removing a Rear Exhaust Fan
1. Determine which node contains the failed fan and power down the node with
the operating system.
2. Remove the power cord from the rear of the node as described Section 6-3.
3. Press the release tab on the bottom of the fan and pull it away from rear of
the node.
Installing a Rear Exhaust Fan
1. Press the release tab on the bottom of the fan and insert it into the open fan
bay.
2. Push the fan into the bay until it clicks into the locked position.
Figure 6-22: Replacing a Rear Exhaust Fans