background image

General Information

900077-00, 01/2018

Innovative Hearth Products
DRL6500 Linear Direct-Vent Gas Fireplaces

4

Important Safety Informa-

tion

1. WARNING: Do not operate appliance 

with the glass front removed, cracked, 
or broken. 

2. Do not use this appliance if any part 

has been under water. Immediately 
call a qualified service technician to in-
spect the appliance and to replace any 
part of the control system and any gas 
control which has been under water.

3. Due to high temperatures, the appli-

ance should be located out of traffic 
and away from furniture and draperies.

4. Children and adults should be alerted 

to the hazards of high surface tem-
perature and should stay away to avoid 
burns or clothing ignition. 

5. Clothing or other flammable material 

should not be placed on or near the 
appliance.

6. Young children should be carefully 

supervised when they are in the same 
room as the appliance. Toddlers, 
young children, and others may be sus-
ceptible to accidental contact burns. 
A physical barrier is recommended 
if there are at-risk individuals in the 
house. To restrict access to a fireplace 
or stove, install an adjustable safety 
gate to keep toddlers, young children, 
and other at-risk individuals out of the 
room and away from hot surfaces.

7. Any safety screen, guard or barrier 

removed for servicing an appliance 
must be replaced prior to operating 
the appliance.

8. Installation and repair should be done 

by a qualified service person. The ap-
pliance should be inspected before use 
and at least annually by a professional 
service person. More frequent clean-
ing may be required due to excessive 
lint from carpeting, bedding material, 
et cetera. It is imperative that control 
compartments, burners, and circulat-
ing air passageways of the appliance 
be kept clean. See maintenance in-
structions on 

Page 61

.

L’information de sûreté 

importante

1.  AVERTISSEMENT. Ne pas utiliser l’appareil 

si le panneau frontal en verre n’est pas en 

place, est craqué ou brisé. 

2.  Ne pas se servir de cet appareil s’il a été 

plongé dans l’eau, même partiellement. 

Faire inspecter l'appareil par un technicien 

qualifié et remplacer toute partie du systéme 

de contrôle et toute commande qui ont été 

plongées dans l'eau.

3.  En raison des températures élevées, 

l’appareil devrait être installé dans un en-

droit où il y a peu de circulation et loin du 

mobilier et des tentures.

4.  Les enfants et les adultes devraient être 

informés des dangers que posent les tem-

pératures de surface élevées et se tenir à 

distance afin d’éviter des brûlures ou que 

leurs vêtements ne s’enflamment.

5.  On ne devrait pas placer de vêtements 

ni d’autres matières inflammables sur 

l’appareil ni à proximité.

6.  Les jeunes enfants devraient être surveillés 

étroitement lorsqu’ils se trouvent dans la 

même pièce que l’appareil. Les tout petits, 

les jeunes enfants ou les adultes peuvent 

subir des brûlures s’ils viennent en contact 

avec la surface chaude. Il est recommandé 

d’installer une barrière physique si des 

personnes à risques habitent la maison. 

Pour empêcher l’accès à un foyer ou à un 

poêle, installez une barrière de sécurité 

; cette mesure empêchera les tout petits, 

les jeunes enfants et toute autre personne 

à risque d’avoir accès à la pièce et aux 

surfaces chaudes.

7.  Tout écran ou protecteur retiré pour per-

mettre l’entretien de l’appareil doit être 

remis en place avant de mettre l’appareil 

en marche.

8.  L’installation et la réparation devrait être 

confiées à un technicien qualifié. L’appareil 

devrait faire l’objet d’une inspection par un 

technicien professionnel avant d’être utilisé 

et au moins une fois l’an par la suite. Des 

nettoyages plus fréquents peuvent être 

nécessaires si les tapis, la literie, et cetera 

produisent une quantité importante de pous-

sière. Il est essentiel que les compartiments 

abritant les commandes, les brûleurs et les 

conduits de circulation d’air de l’appareil 

soient tenus propres. Voyez les instructions 

d’entretien à la 

page 61

.

Información importante de 

seguridad

1.  ADVERTENCIA: No opere el artefacto con el 

frente de vidrio quitado, agrietado o roto.  

2.  No use este artefacto si alguna de sus partes 

ha estado bajo agua. Llame de inmediato 
a un técnico de servicio calificado para 
que inspeccione el artefacto y reemplace 
cualquier parte del sistema de control y 
cualquier control de gas que haya estado 
bajo agua.

3.  Debido a las altas temperaturas, el artefacto 

debe situarse fuera de las áreas de tráfico y 
lejos del mobiliario y cortinas.

4.  Se debe alertar a los niños y adultos sobre 

los peligros de las altas temperaturas en la 
superficie y que se mantengan alejados para 
evitar quemaduras o ignición de la ropa. 

5.  No debe colocarse ropa u otros materiales 

inflamables sobre y cerca del artefacto.

6.  Se debe supervisar de cerca a los niños 

cuando estén en el mismo cuarto que el 
artefacto. Los niños pequeños, los jóvenes 
y otras personas pueden ser susceptibles 
a quemaduras por contacto accidental. Se 
recomienda instalar una barrera física si hay 
personas en riesgo en la casa. Para restringir 
el acceso a una chimenea o estufa, instale 
una puerta de seguridad ajustable para 
mantener a los niños pequeños, jóvenes y 
otras personas en riesgo fuera del cuarto y 
lejos de las superficies calientes.

7.  Cualquier malla o resguardo de seguridad 

quitado para dar servicio a un artefacto, debe 
reinstalarse antes de operar el artefacto.

8.  Una persona de servicio competente debe 

realizar la instalación y reparación. Una 
persona de servicio profesional debe 
inspeccionar el artefacto antes de usar al 
menos una vez por año. Se puede requerir 
limpieza más frecuente debido a la pelusa 
excesiva del alfombrado, del material de 
cobijas, etc. Es imprescindible mantener 
limpios los compartimientos de control, los 
quemadores y los pasajes de circulación del 
aire del artefacto. Ver las instrucciones de 
mantenimiento en la 

página 6

1

.

IMPORTANT SAFETY INFORMATION

Содержание DRL6500

Страница 1: ...eur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoivent treassur spar u...

Страница 2: ...VITRE EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas...

Страница 3: ...oca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio...

Страница 4: ...ltes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un...

Страница 5: ...ommonwealth of Massachusetts 11 Cold Climate Insulation 11 Manufactured Home Requirements 12 Location 12 Vent Termination Clearances 13 Minimum Clearances to Combustibles 15 Wall Finishes Surrounds Ma...

Страница 6: ...or its operating controls is dangerous Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning CARBON MONOXIDE POISONING...

Страница 7: ...The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous Provide adequate clearances around air openings and adequate accessibility clearance f...

Страница 8: ...this system may be dangerous and may void the warranty Electronic fireplaces are designed with an electronic intermittent pilot ignition system External electrical power is required to operate these u...

Страница 9: ...in bedrooms aftermarket mobile homes and manufactured homes The installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edi...

Страница 10: ...Manifold OUT Air shutter adjustment lever Lower right corner of fireplace NOTE Before accessing the test ports the fireplace must be OFF and COLD Turn OFF the main gas supply before connecting to the...

Страница 11: ...pair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts The flexible gas line connector used shall not exceed 36 914 mm in length The individual manual shutoff must...

Страница 12: ...ON In selecting the location the aesthetic and functional use of the fireplace are primary concerns However vent system routing to the exterior and access to the fuel supply are also important The fir...

Страница 13: ...Vents above Flat or Sloped Roofs NFPA 54 ANSI Z223 1 Gas Vent Rule Roof Pitch Termination Height Flat to 6 12 1 0 ft 0 3 m 6 12 to 7 12 1 25 ft 0 38 m 7 12 to 8 12 1 5 ft 0 46 m 8 12 to 9 12 2 0 ft 0...

Страница 14: ...7 mm minimum 5 127 mm minimum G Clearance to inside corner 2 51 mm minimum 2 51 mm minimum H Clearance to each inside of center line extended above meter regulator assembly 36 910 mm within a height o...

Страница 15: ...y horizontal inclined vent component See Page 19 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it Hearth Extension A hearth extensio...

Страница 16: ...102 2 51 in mm 18 457 20 508 22 559 24 610 26 660 28 711 Fireplace Mantel depth INSTALLATION PREPARATION The fireplace is shipped with all gas controls and components installed and pre wired Before in...

Страница 17: ...Framing Secure and install Heat Shield Page 21 Venting 6 Select a Horizontal or Vertical Vent System Page 21 7 Install the Vent Restrictor if necessary Page 21 8 Install the Vent System Page 25 Electr...

Страница 18: ...OF THE FIREPLACE 1 Frame the fireplace as illustrated in Table 10 All framing details must allow for a minimum clearance to combustible framing members as shown in Table 8 Steel studs are strongly re...

Страница 19: ...4 models straight vent section and 90 elbow off appliance vent collar NOTE Theverticalcenterlineofthehorizontalterminationvent pipeisNOTthesameas theverticalcenterlineoftheventframeopeningbecauseoffir...

Страница 20: ...must be routed assembled and made of materials that are in strict accordance with local codes and regulations Never use galvanized or plastic pipe NOTE See Page 55 for more information on Accessing th...

Страница 21: ...up Figure 13 The vent restrictor is held in place by friction The vent restrictor must not be visible inside the firebox NOTE If the baffle and back panel are installed remove them before installing...

Страница 22: ...g a vent system with a vertical vent run up to 6 ft through an exterior wall no vent restrictor is required If installing more than 6 ft of vertical venting install the restrictor Figure 13 from insid...

Страница 23: ...lescopic vent section has an effective length of from 1 1 2 to 7 1 2 38 191 mm The telescopic vent section is fitted with a locking inclined channel end identical to a normal vent section component an...

Страница 24: ...2 0 3 480 40 1 1 0 0 10 12 79 5 6 625 0 1 0 2 0 3 492 41 1 0 1 0 10 12 81 6 75 0 0 0 1 1 2 499 5 41 625 0 0 0 1 10 11 91 5 7 625 0 0 2 0 1 3 504 42 1 0 0 1 10 12 93 7 75 0 0 0 0 2 2 511 5 42 625 0 0 0...

Страница 25: ...he roof The minimum vent height above the roof and or adjacent walls is specified in ANSI Z223 1 In Canada the current CAN CGA B149 1 installation code by major building codes Always consult your loca...

Страница 26: ...ing the firestop spacer must be installed on the top side of the joist Route the vent sections through the framed opening and secure the firestop spacer with 8d nails or other appropriate fasteners at...

Страница 27: ...ent section and position such that the vent column rises vertically use carpenters level Nail along perimeter to secure flashing or adjust roofing to overlap the flashing edges at top and sides only a...

Страница 28: ...Tables NOTE If the parameters of your vent run fall outside the parameters described herein consider installing the Power Vent Kit NOTE Rise per foot run ratios are acceptable all the way to level For...

Страница 29: ...ing u Vertical firestop spacer must be used anywhere vent pipe passes through a combustible floor or ceiling Horizontal firestop spacer must be used anywhere vent pipe passes through a combustible wal...

Страница 30: ...a 90 elbow 1 Analyze the vent route and determine the number of vent sections and elbows required See Effective Vent Length on Page 22 for more information Plan the venting so that a joint does not oc...

Страница 31: ...f the terminus of the last section is not within this distance use the telescopic vent section SV4 5LA as the last vent section Table 21 lists the additional venting components needed in addition to t...

Страница 32: ...mination MaximumWallThickness 9 1 4 235mm ExteriorSurfaceofSiding ExteriorSurfaceof Framing 6 to9 1 4 152to235mm 1 1 4 MaximumRecessofthe SquareTerminationintoExterior FinishingMaterial SV4 5HT 2 Squa...

Страница 33: ...res Tables NOTE Secure Vent rigid vent pipe and terminal are shown in the figures Secure Flex flexible vent pipe and terminal may also be used NOTE If the parameters of your vent run fall outside the...

Страница 34: ...t restrictor if required A 90 elbow may NOT be attached directly to the appliance collar A minimum 12 pipe section must be used between the fireplace collar and a 90 elbow Table 24 Top Vent Three 90 E...

Страница 35: ...flexible pipe and slide the flexible vent over the inner and outer adaptor collars NOTE Outer vent pipe is pulled away to show inner vent pipe details 1 3 4 44 mm flexible vent and adaptor outer coll...

Страница 36: ...t circumference than Secure Vent collars Secure Flex vent has a longer center tube to improve ease of installation 9 Complete the Field Wiring CAUTION The ground supply lead must be connected to the w...

Страница 37: ...box can be moved to the bottom of the fireplace for bottom electrical entry 3 Remove the cover plate knockout then feed the power supply wire through the knockout opening and into the unit junction bo...

Страница 38: ...re 32 All codes require a shutoff valve mounted in the supply line Figure 33 illustrates the method for connecting the gas supply The flex line method is acceptable in the U S however Canadian require...

Страница 39: ...a gas leak test solution also known as bubble leak solution NOTE Using a soapy water solution is an effective leak test solution but it is not recommended because the soap residue that is left on the...

Страница 40: ...Glass Media 16 Install the Baffle 1 With the baffle oriented as shown in Figure 35 slide the rear tabs into the slots in the back panel Figure 35 Baffle Baffle Back Panel Clip Firebox Ceiling Tabs 2...

Страница 41: ...opened The length and configuration of the chimney vent will affect flame appearance A fireplace operated with the air shutter opened too far may have flames that appear blue and transparent These wea...

Страница 42: ...ve Hearth Products DRL6500 Linear Direct Vent Gas Fireplaces 42 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Figure 37 Flame Appearance Table 26 Main Burner Shutter Opening Factory Setting Models Natu...

Страница 43: ...Do NOT remove brackets for cleanface finish they are required for proper combustion 2 Secure heat shield to top front of unit with two screws NOTE Install a second field supplied noncombustible board...

Страница 44: ...nsert remaining barrier assembly into bezel assembly and attach with screws 9 Reinstall the door 10 Attach surround to surround support with six 6 screws 11 Hang barrier assembly on door and snap unde...

Страница 45: ...43 Correctly align polarity 2 Insert the 4 provided AA batteries into the receiver battery bay behind the wall switch plate Correctly align polarity 3 Position the wall switch receiver three position...

Страница 46: ...TO SCALE 20 Attach the Safety in Operation Warning Labels 1 Attach the furnished safety instruction labels at all fireplace operation and control points Page 47 NOTE The installer MUST ensure these wa...

Страница 47: ...liminer la poussi re et les traces degraisseoud huile Collezl tiquettesurlebo tier de la t l commande Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propri taire En c...

Страница 48: ...5FA 0 12 to 0 12 Adjustable Flashing 77L80 SV4 5FB 7 12 to 12 12 Adjustable Flashing 77L81 SV4 5SC6 Storm Collar 6 pack H6183 SV4 5HF5 Firestop Spacer 5 rigid H6184 SF4 5HF5 Firestop Spacer 5 flex H2...

Страница 49: ...Termination for flex without flex 56L74 SFVT30 VerticalTerminationforflex flatto6 12 withflexadaptor sectionofrigidvent roof supportcollarassembly roofflashingand stormcollar see750052M 77L87 SFKIT12...

Страница 50: ...r r duire au minimum le risque d incendie d explosion ou la production de monoxyde de carbone pouvant causer des dommages mat riels des blessures ou la mort Le tecnicien agr est responsable de l insta...

Страница 51: ...the burner assembly with the attached venturi tube Figure 44 8 Remove the control compartment access door and gasket Figure 44 Figure 44 Removing the Burner and Accessing the Control Compartment Contr...

Страница 52: ...test the new pressure regulator assembly and all gas line joints for leaks Page 55 20 Attach the conversion information label to the rating plate 21 Locate the external test ports just under the door...

Страница 53: ...anemia those under the influence of alcohol and those at high altitudes NOTE Do not place furniture or other combustible materials within 36 of the front of viewing area s NOTE Children and adults sho...

Страница 54: ...arl e dans la r sidence du propri taire 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour liminer la poussi re et les traces de graisseoud huile Collezl tiquettesurlebo tierde la t l commande Fi...

Страница 55: ...er Gas Controls Shutoff Valves As part of your fireplace installation the installer may have provided a readily accessible gas shutoff valve near your fireplace Make sure this valve is fully open befo...

Страница 56: ...ted manually ON OFF 1 To test the batteries in the wall switch receiver press the handheld remote control ON OFF key Figure 43 one time If the wall switch receiver emits a beep the batteries have enou...

Страница 57: ...stat 1 Repeatedly press the THERMOSTAT key to cycle the thermostat between ON OFF and SMART modes Figure 48 2 To change the temperature scale F to C With the system in the OFF position press the THERM...

Страница 58: ...rebox Liners Install the side panels from kit 1 Align screw hole in top flange of side panel with upper hole in inside wall of fireplace 2 Align screw holes in bottom flanges of side panel with holes...

Страница 59: ...ENT Une barri re con ue pour r duire le risque de br lure par le hublot chaude est fournie avec l appareil et doit tre install WARNING Do not operate appliance with the glass front removed cracked or...

Страница 60: ...oor alignment and sealing are important to the operation and performance of the fireplace Ensure the door seal is contacting the frame and that no air leaks are present 3 Align the screw holes below t...

Страница 61: ...sembly and proper sealing of the venting system components However more frequent periodic inspections and cleanings should be performed by the homeowner NOTE Prior to the first use of the fireplace an...

Страница 62: ...e reinstalling Reinstalling the glass media Carefully follow the placement instructions Page 58 This will ensure a proper flame and safe combustion NOTE Improper positioning of media can create carbon...

Страница 63: ...flame rod and hood Ensure the pilot flame engulfs the flame sensor Checking Vent System Qualified Service Technician Remove baffle inspect the vent system at the top and at the base within the firebo...

Страница 64: ...h Designer style floors Reflection style floors do not use glass media Glass Media Catalog Model Description H8412 CRSHGL RBLK Bag of Glass Media Reflective Black H8424 CRSHGL RBLU Bag of Glass Media...

Страница 65: ...dels F2265 BZL BRNI RAP54 Brushed Nickel 54 models Power Vent Kits Power Vent Kits and Extended Wire Harness Catalog No Model No Description H7387 LPVK 110 Power Vent Kit H8574 PVK RHAP Power Vent Ada...

Страница 66: ...onal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE OPERATING smell all around the appl...

Страница 67: ...ez l appareil sous tension 9 Placez l interrupteur du r cepteur en position REMOTE 10 Appuyez sur le bouton ON OFF pour s lectionner ON 11 Si applicable Ajustez le thermostat sur la t l commande l aju...

Страница 68: ...ng call a service technician if necessary d Air in the gas line Purge gas line of air call a service technician if required e Unit is not receiving power Replace unit battery backup 3 The main Burner...

Страница 69: ...1 1 12 NG Pilot Assembly H7268 1 H7268 1 13 Propane Pilot Assembly H7269 1 H7269 1 14 Control Module H8656 1 H8856 1 15 Glass Door Latch H8433 1 H8433 1 16 Flex Gas Connector Assembly 93L32 1 93L32 1...

Страница 70: ...og Number Qty 26 Remote Control Transmitter Kit H8753 1 H8753 1 27 Glass Door H8799 1 H8431 1 28 Top Baffle H8787 1 H8583 1 29 Blower Assembly FBK 100 80L84 1 80L84 1 30 Barrier J7427 1 J7426 1 If the...

Страница 71: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 72: ...place serial number Date fireplace was Installed Type of gas fireplace uses Dealer name P900077 00 IHP reserves the right to make changes at any time without notice in design materials specifications...

Отзывы: