INSTALLER:  LEAVE THIS MANUAL WITH THE APPLIANCE.

CONSUMER:  RETAIN THIS MANUAL FOR FUTURE REFERENCE.

INSTALLATION AND 

OPERATING INSTRUCTIONS

1.2A

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 

103 Miller Drive, Crittenden, Kentucky, USA, 41030

Phone (705)721-1212 • Fax (705)722-6031 • www.napoleon

fi

 replaces.com • [email protected]

SAFETY INFORMATION

!

WARNING

If the information in these instructions are 
not followed exactly, a fi re or explosion 
may result causing property damage, 
personal injury or loss of life.

- Do not store or use gasoline or other fl ammable 
vapors and liquids in the vicinity of this or any 
other appliance.

- WHAT TO DO IF YOU SMELL GAS:
• 

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not use        
any phone in your building.

• 

Immediately call your gas supplier from a        
neighbour’s phone.  Follow the gas supplier’s        
instructions.

• 

If you cannot reach your gas supplier, call the        
fi re department.

- Installation and service must be performed by a 
qualifi ed installer, service agency or the supplier.

CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

BGD42CFN

NATURAL GAS

BGD42CFP

PROPANE

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS.

Содержание BGD42CFN

Страница 1: ...s of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch a...

Страница 2: ...LLATION 21 4 4 2 VERTICAL AIR TERMINAL INSTALLATION 22 4 4 3 APPLIANCE VENT CONNECTION 23 4 5 MOBILE HOME 23 4 6 GAS INSTALLATION 24 4 7 OPTIONAL WALL SWITCH INSTALLATION 24 5 0 FRAMING 25 5 1 MINIMUM...

Страница 3: ...See the section INSTALLATION FRAMING See the section VENTING and INSTALLATION See the section FRAMING See the sections MINIMUM ENCLOSURE CLEARANCES for drywall or other combustible material See the se...

Страница 4: ...g the appliance It is imperative that the control compartments burners and circulating blower and its passageway in the appliance and venting system are kept clean The appliance and its venting system...

Страница 5: ...tallation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT WITH THE GLASS DOOR OPE...

Страница 6: ...tending the full width and depth If the optional fan or blower is installed the junction box must be electrically connected and grounded in accordance with local codes use the current CSA C22 1 Canadi...

Страница 7: ...N 3280 DANS LE CAS OU CETTE NORME D ETATS UNIS NE PEUT ETRE APPLIQUEE SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFAC...

Страница 8: ...ENT NON COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARANCE TO COMBUSTIBLES FOR BOTH VERTICAL AND HORIZONTAL RUNS SPACERS ARE ATTACHED TO THE INNER PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN E...

Страница 9: ...tructed at all times Examine the air terminal at least once a year to verify that it is unobstructed and undamaged Rigid and flexible venting systems must not be combined Different venting manufacture...

Страница 10: ...ICAL VENT INSTALLATIONS 38 1 2 MIN PLUS RISE 18 MAX 40 FT 16 MIN See venting section NOTE When terminating vertically the restrictor plate W500 0205 must be installed Refer to RESTRICTING VERTICAL VEN...

Страница 11: ...MINATION Use the periscope kit to locate the air termination above grade The periscope must be installed so that when final grading is completed the bottom air slot is located a minimum of 12 above gr...

Страница 12: ...arance above the roof O 2 2 Clearance from an adjacent wall including neighbouring buildings P 8 8 Roof must be non combustible without openings Q 3 3 See chart for wider wall dimensions R 6 6 See cha...

Страница 13: ...e vertical rise equal to or greater than the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 3 6 DEFINITIONS 3 7 ELBOW VENT LENGTH VALUES 14 2 For the following sy...

Страница 14: ...HO 03 one 45 elbow two 90 elbows 135 03 225 135 2 7 FT HT HR HO 4 5 2 7 7 2 FT HT VT 7 2 8 15 2 FT Formula 1 HT VT 7 2 8 Formula 2 HT VT 40 FT 15 2 40 Since both formulas are met this vent configurat...

Страница 15: ...e 45 elbow four 90 elbows 135 03 405 135 8 1 FT HT HR HO 5 5 8 1 13 6 FT HT VT 13 6 5 5 19 1 FT Formula 1 HT 4 2 VT 4 2 VT 4 2 x 5 5 FT 23 1 FT 13 6 23 1 Formula 2 HT VT 24 75 FT 19 1 24 75 Since both...

Страница 16: ...lbow the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet Example 3 V1 5 FT V2 10 FT VT V1 V2 5 10 15 FT H1 3 FT H2 2 5 FT HR H1 H2 3 2 5 5 5 FT HO 03 one 45 three 90 elbows 135 03 45...

Страница 17: ...e this formula is not met this vent configuration is unacceptable Formula 2 HT VT 40 FT 15 9 40 Since only formula 2 is met this vent configuration in unacceptable and a new fireplace location or vent...

Страница 18: ...SION OR ASPHYXIATION IMPROPER SUPPORT OF THE ENTIRE VENTING SYSTEM MAY ALLOW VENT TO SAG AND SEPARATE USE VENT RUN SUPPORTS AND CONNECT VENT SECTIONS PER INSTALLATION INSTRUCTIONS RISK OF FIRE DO NOT...

Страница 19: ...B Place the firestop bottom against the firestop top and secure the two together Adjust the assembly to ensure it is tight to the vent Secure firestop to wall This restricts cold air from being drawn...

Страница 20: ...in the required clearance to combustibles Once the vent pipe is installed in its final position apply sealant between the pipe and the firestop assembly C In the attic slide the vent pipe collar down...

Страница 21: ...ake weather tight by sealing with caulking not supplied D If more vent pipe needs to be used to reach the appliance couple them together as illustrated The vent system must be supported approximately...

Страница 22: ...tor leaving a min 3 4 of the air terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure that the air terminal connector...

Страница 23: ...Home Listed appliance comes factory equipped with a means to secure the unit Built in appliances are equipped with 1 4 diameter holes located in the front left and right corners of the base Use 10 hex...

Страница 24: ...IGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PURGING OF THE GAS SUPPLY LINE SHOULD BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN AS...

Страница 25: ...F BLOWN IN INSULATION MAKE SURE INSULATION AND OTHER MATERIALS ARE SECURED WHEN CONSTRUCTING THE ENCLOSURE ALLOW FOR FINISHING MATERIAL THICKNESS TO MAIN TAIN CLEARANCES FRAMING OR FINISHING MATERIAL...

Страница 26: ...3 4 46 1 2 14 MIN 1 1 2 MAX 49 MINIMUM ENCLOSURE HEIGHT NOTE Do not build into this area it must be left clear to provide adequate clearance for the vent in this 14 wide area centered along the front...

Страница 27: ...It is not necessary to install a hearth extension with this fireplace system When roughing in the fireplace raise the fireplace to accommodate for the thickness of the finished floor materials i e til...

Страница 28: ...e Venting Section 2 2 38 1 2 MINIMUM PLUS RISE 12 4 1 2 49 2 37 0 IF NON COMBUSTIBLE FINISHING IS USED SUCH AS BRICK AND STONE COMBUSTIBLE NON COMBUSTIBLE NON COMBUSTIBLE 2 This appliance is supplied...

Страница 29: ...ireplace 8 MANTEL 2 4 6 12 14 16 18 6 1 2 MIN USE ONLY NON COMBUSTIBLE MATERIAL SUCH AS CEMENT BOARD CERAMIC TILE MARBLE ETC WHEN FINISHING TO THE FIREPLACE DO NOT USE WOOD OR DRYWALL WARNING WARNING...

Страница 30: ...ENING OF THE APPLIANCE THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON COMBUSTIBLE MATERIALS SUCH AS BRICK MARBLE GRANITE ETC PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMEN...

Страница 31: ...the pilot assembly Rest the log against the back wall of the firebox 6 5 2 Move the two small logs 2 3 into position lining up the studs located on the burner with the holes on the bottom of the logs...

Страница 32: ...hould be taken to not block the burner ports Blocked burner ports can cause an incorrect flame pattern carbon deposits and delayed ignition Phazertm logs glow when exposed to direct flame Use only cer...

Страница 33: ...rocedure to re assemble SPACERS SPACERS ERS WARNING RISK OF FIRE AND ELECTRICAL SHOCK TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESS...

Страница 34: ...not touch the appliance base or the firebox Attach the connectors from the black and white wires to the thermal switch and secure the thermal switch bracket to the bottom left of the unit using the s...

Страница 35: ...ot burner to be lit until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless...

Страница 36: ...9 3 P I P I L O T N O L O T HI L O F F O A B PILOT SCREW PILOT BURNER THERMOCOUPLE THERMOPILE 9 2 VENTURI ADJUSTMENT This appliance has an air shutter that has been factory set open according to the c...

Страница 37: ...E UPPER 3 8 TO 1 2 OF THERMOCOUPLE THERMOPILE P I P I L O T N O L O T HI L O F F O 9 5 RESTRICTING VERTICAL VENTS Vertical terminations may display a very active flame As this appearance is not desira...

Страница 38: ...2 Keep the control compartment media burner air shutter opening and the area surrounding the logs clean by vacuuming or brushing at least once a year 3 Check to see that all burner ports are burning C...

Страница 39: ...lding the glass in place Careful not to break the glass GLASS GASKET DOOR FRAME GLASS RETAINER 10 2 1 10 2 2 10 2 3 WARNING DO NOT USE SUBSTITUTE MATERIALS GLASS MAY BE HOT DO NOT TOUCH GLASS UNTIL CO...

Страница 40: ...E ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD WARNING COMPONENTS REF NO BGD42CF DESCRIPTION 1 W357 0001 PIEZO IGNITER 2 W680 0004 THERMOPILE 3 W680 0005 THERMOCOUPLE 4 W010 0800 NA...

Страница 41: ...PAINT BLACK 13OZ 43 W361 0041 VERMICULITE FLEXIBLE VENT KITS REF NO BGD42CF DESCRIPTION GD420 5FT 44 W730 0010 5 FLEXIBLE VENT PIPE 5 5FT C W SPACERS 45 W730 0012 8 FLEXIBLE VENT PIPE 5 5FT GD430 10FT...

Страница 42: ...501 HEAT GUARD 63 W585 0096 SOFFIT HEAT SHIELD 64 W010 0067 ASSEMBLY SUPPORT RING 5 8 65 W175 0170 DURA VENT ZERO CLEARANCE ADAPTOR 66 W170 0086 VENT PIPE COLLAR 67 W585 0092 VENT PIPE SHIELD 68 W175...

Страница 43: ...y Loosen and tighten thermocouple Clean thermocouple and valve connection Replace thermocouple Replace valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch ther...

Страница 44: ...d water solution Flames are very aggressive Door is ajar Tighten screws holding door in place Carbon is being deposited on glass logs or combustion chamber surfaces Air shutter has become blocked Ensu...