Installation
900077-00, 01/2018
Innovative Hearth Products
DRL6500 Linear Direct-Vent Gas Fireplaces
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INSTALLATION
PACKAGING
All models include
The assembled vented gas fireplace heater is packaged with:
• Literature Kit (Installation and Operation Instructions (this manual), Hot Glass Safety Flyer, and
Safety-In-Operation Warning Labels)
• Vent restrictor assembly
• Baffle (shipped on fireplace floor)
• Heat shield and insulation (shipped inside the fireplace)
• Three (3) Non-combustible fiber boards
• Three (3) AAA batteries
• Handheld remote control (transmitter)
• Remote control receiver (wall switch) assembly with four (4) AA batteries
• Barrier
• 1 Bag of reflective Black Glass Media
Optional accessories
• Surround kit
• Bezel kit
• Power vent kit (Requires DRL6500 power vent adaptor kit)
• Gas conversion kit
• Glass Media Kits - Reflective Blue, Platinum, Goldfinger, and Copper
INTRODUCTION
These vented gas fireplace heaters are sealed combustion, air-circulating gas fireplaces designed for residential,
manufactured home, and commercial applications. Direct-vent appliances operate with the combustion chamber
isolated from the indoor environment. All air for combustion is brought in from the outside, and exhaust gases are
vented through the same direct-vent, coaxial (intake/exhaust) vent system.
These appliances are designed to operate on natural or propane gas only. The use of other fuels or fuel combinations
will degrade the performance of this system, may be dangerous, and may void the warranty.
Electronic fireplaces are designed with an electronic intermittent pilot ignition system. External electrical power is
required to operate these units. In the event of a power outage, four (4) AA batteries (in battery holder) provide
backup power for fireplace operation.
Batteries will operate the gas valve OPEN/CLOSE and pilot ON/OFF functions only. Electrical power (120V AC line
voltage) is required to operate the following components:
• Blower
• Power vent system
A remote control system is included with all models and provides remote operation of several fireplace functions
(manual adjustment of the gas valve settings is not possible).
NOTE:
Installation and repair should be done by a qualified service person. The appliance should be inspected
before use and at least annually by a professional service person. More frequent cleaning might be required due to
excessive lint from carpeting, bedding material, et cetera. It is imperative that control compartments, burners, and
circulating air passageways of the appliance be kept clean.
Remarqué :
L’installation et la réparation devrait être confiées à un technicien qualifié. L’appareil devrait faire
l’objet d’une inspection par un technicien professionnel avant d’être utilisé et au moins une fois l’an par la suite.
Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera produisent une quantité
importante de pous-sière. Il est essentiel que les compartiments abritant les commandes, les brûleurs et les
conduits de circulation d’air de l’appareil soient tenus propres.
NOTE:
Diagrams and illustrations are not necessarily shown to scale.