background image

Operation 

900994-00K, 07/2021 

Innovative Hearth Products
DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces

61

 WARNING

The door should easily close without needing to be pressed down. If it has to be pressed 

down to close, the gasket in the top of the door should be dressed so it lays on the glass.

Installing the glass door

1. 

Visually inspect the gasket on the backside of the glass door.

NOTE: 

The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located. 

Make sure the bead is not rolled into the channel at the top of the door, but remains flat against the top of the 

glass.

2. 

Position the door in front of the firebox opening with the bottom of the door held away from the fireplace at a 

45° angle 

(

Figure 49

). 

Hook the top flange of the door frame over the top of the firebox frame.

NOTE: 

Ensure the glass door is centered—with even spacing on each side.

3. 

Let the bottom of the glass door swing gently in towards the fireplace ensuring that the gasket seats evenly 

as the door draws shut. Securely fasten the two (2) latches beneath the firebox floor to the door V-flange. 

IMPORTANT NOTE: 

The door must close without force.  When installed properly, the bottom of the door should 

not have interference with the fireplace in order to close.  If it does, remove the door and inspect the door gasket 

to ensure it is even and not rolled up at the top. 

SEE WARNING IN Figure

 49

.

4. 

Install the barrier assembly.

Removing the glass door

1. 

Remove the barrier assembly

2. 

Detach the door latches beneath the firebox floor.

3. 

Carefully grip the door at the top and bottom, and remove it from the fireplace. Place the door in a safe location 

for later reinstallation.

Figure 49 - Glass Door

Latch

Glass 

Door

Figure 50 - Barrier

NOTE: When installing the glass door, ensure the spacing on both sides is even and equal.

1

2

INSPECT GASKET AND ADJUST IF NECESSARY (see pictures above)

(1) Ensure the gasket is properly positioned, and area to keep clear, is as shown.

(2) Inspect gasket after installation to ensure it appears as shown above.

Inside view 

of glass door 

showing 

proper gasket 

positioning

With door installed, 

ensure gasket is po-

sitioned as shown.

Gasket

Gasket

SEE WARNING BELOW

35” Barrier - Cat. No. F4248
45” Barrier - Cat. No. F4249

55” Barrier - CAT No. F4250

NOTICE: All DRL2000 & DRL3500 series fireplaces 

require 

a barrier (provided) to reduce the risk of burns 

from the hot viewing glass. The barrier must be in-

stalled prior to operation.

Replacement barrier catalog numbers are shown here.

f i r e - p a r t s . c o m

Содержание DRL2000 Series

Страница 1: ...un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoivent treassur spar un installateur ou...

Страница 2: ...tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre chaude et doit tre install pour la protection Des enfants et Des personnes risques Vea el volante...

Страница 3: ...toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidr...

Страница 4: ...ion Preparation 17 Installation Installation Sequence 17 Construct the Fireplace Framing 17 Prepare the Fireplace Top Spacers 21 Route the Gas Supply Line to the Fireplace 21 Installing Header Shield...

Страница 5: ...bir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po...

Страница 6: ...rous Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning CARBON MONOXIDE POISONING Early signs of carbon monoxide po...

Страница 7: ...ccessibility clearance for service and proper operation Never obstruct the front openings of the appliance These appliances are designed as supplemental heaters Therefore it is advisable to have an al...

Страница 8: ...a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etcetera It is imperative that control compartment burners and circulating a...

Страница 9: ...tructions 900949 00 provided with this appliance Table 1 Input Rate BTU HR Gas Valves Burner Model Natural Gas Propane LP Gas Field Converted High Rate Low Rate High Rate Low Rate DRL2035 15 000 13 00...

Страница 10: ...diminish 4 for every 1 000 ft of altitude IN CANADA CAN CGA 2 17 M91 HIGH ALTITUDE THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURER S AUTHORIZED REPRESENTATIVE IN ACCORDANCE WITH THE REQUIREMENT...

Страница 11: ...noxide detector must comply with NFPA 720 be ANSI UL 2034 listed and be ISA certified A metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum h...

Страница 12: ...urniture and draperies En raison des temp ratures lev es l appareil devrait tre install dans un endroit o il y a peu de circulation et loin du mobilier et des tentures The location should also be free...

Страница 13: ...to 14 12 5 0 ft 1 52 m 14 12 to 16 12 6 0 ft 1 83 m 16 12 to 18 12 7 0 ft 2 13 m 18 12 to 20 12 7 5 ft 2 29 m 20 12 to 21 12 8 0 ft 2 44 m 12 X Roof pitch is X 12 2 ft minimum 2 ft minimum Lowest disc...

Страница 14: ...onmechanical air supply inlet to building or the combustion air inlet to any other fireplace 6 150 mm for fireplaces 10 000 Btu h 3 kW 9 230 mm for fireplaces 10 000 Btu h 3 kW and 50 000 Btu h 15 kW...

Страница 15: ...m 3 77 mm above any horizontal inclined vent component See Page 23 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it 6 153 mm if opti...

Страница 16: ...nimum clearance requirements include any projections such as shelves window sills mantels etc above the fireplace NOTE To avoid heat related finish damage we recommend the use of high temperature pain...

Страница 17: ...l Vent System Page 23 9 Install the Vent Restrictor if necessary Page 23 10 Connecting the Vent Pipe Page 25 11 Install the Vent System Page 28 Electrical Connection 12 Complete the Field Wiring Page...

Страница 18: ...1 2 547 29 737 42 1067 18 458 N A A Minimum opening size additional 1 8 per side is recommended G For installations with 12 section directly off unit then elbow NOTE Framing specifications do NOT app...

Страница 19: ...ith HeatFlo Kit for Recessed Wall Pocket E B A G H C F F D A B E G H C with HeatFlo Kit for Flush Wall with HeatFlo Kit for Recessed Wall Pocket E B A G H C F F D A B E G H C with HeatFlo Kit for Flus...

Страница 20: ...replace Ceiling Wall HeatFlo Vent Opening B C A Min 76 1 930 m Max 20 ft 6 096 m Base of Fireplace Figure 6A Dimensions for Television TV Installed Above Fireplace on a Recessed Wall Pocket Television...

Страница 21: ...kets NOTE DRL3535TEN and DRL3545TEN models require a 4 75 non combustible fireboard provided while DRL2035TEN and DRL2045TEN models require a 2 75 non combustible board provided The gas supply line sh...

Страница 22: ...Step 1 Remove screw holding standoff to firebox bend to 4 tall as seen above and attach screw Step 2 Install the header shield by sliding it into the slot in the standoffs Step 3 Fireboard standoff ca...

Страница 23: ...oved vent components See Pages 28 31 vertical and Pages 34 38 horizontal NOTE This fireplace must be vented directly to the outside WARNING The vent system may not service multiple appliances and must...

Страница 24: ...rea raised Base Vent Restrictor Base Vent Restrictor Wing With break away raised Minimal Restrictor Vent Restrictor with Vertical Terminations When vertically terminating the vent system through the r...

Страница 25: ...equired length The SV4 5LA Telescopic Vent Section has an effective length of from 1 1 2 to 7 38 to 178 mm The SV4 5LA is fitted with a locking inclined channel end identical to a normal vent section...

Страница 26: ...ctions in Figure 18 NOTE Same installation applies if installed in a corner STEP 1 Locate the two 2 flat elbow shields STEP 2 Bend the three 3 tabs 90 degrees as shown below STEP 3 Attach the two 2 sh...

Страница 27: ...5 38 75 0 0 0 0 10 10 69 5 75 0 0 0 2 0 2 475 5 39 625 0 1 0 0 10 11 73 5 6 125 1 0 0 2 0 3 480 40 1 1 0 0 10 12 79 5 6 625 0 1 0 2 0 3 492 41 1 0 1 0 10 12 81 6 75 0 0 0 1 1 2 499 5 41 625 0 0 0 1 10...

Страница 28: ...figures Secure Flex pipe may also be used A table summarizes each configuration s minimum and maximum vertical and horizontal length parameters for a variety of applications 1 Refer to Figure 24 and T...

Страница 29: ...living space above the ceiling level the firestop spacer must be installed on the bottom side of the ceiling If attic space is above the ceiling the firestop spacer must be installed on the top side o...

Страница 30: ...op and both sides of the flashing with waterproof caulking The flashing must overlap the roofing material along the bottom 11 Install the storm collar Install the storm collar supplied with the flashi...

Страница 31: ...HF Secure Flex firestop spacer must be used anytime vent pipe passes through a combustible wall NOTE Two 2 45 elbows may be used in place of one 1 90 elbow The same rise to run ratios as shown in the...

Страница 32: ...f H horizontal run up to a maximum horizontal run of 25 ft Minimum 6 ft and maximum of 60 ft of vertical venting Table 18 Top Vent Three Elbows H H1 Maximum V Minimum feet meters feet meters 5 1 524 E...

Страница 33: ...t Length on Pages 25 27 for more information Plan the venting so that a joint does not occur in the ceiling or roof joists Allow for elbows Figure 18 Page 26 Maintain clearances to combustibles equal...

Страница 34: ...the exterior side of the framing long side up with the 3 spacer clearance at the top Figure 27 Page 33 and nail into place This Wall Heatshield shall be installed using the provided burn screws on th...

Страница 35: ...0K81 or high temperature silicone Figure 28 Venting Connection and Exterior Wall Recessing of the Horizontal Termination Use silicone caulking to seal the top and sides of the termination up to the un...

Страница 36: ...able all the way to at or near level Use a carpenter s level to measure from a constant surface and adjust the support straps as necessary NOTE SV4 5VF Secure Vent SF4 5VF Secure Flex firestop spacer...

Страница 37: ...ne Foot Vent Section Required When using Secure Flex use ceiling firestop spacer SF4 5VF When using Secure Flex use wall firestop spacer SF4 5HF Wall firestop spacer SV4 5HF Ceiling firestop spacer SV...

Страница 38: ...hows a 1 V to 5 H ratio For every 1 ft of V vertical you are allowed 5 ft of H horizontal run up to a maximum horizontal run of 20 ft 6 096 m NOTE The Wall Heatshield provided shall be installed per i...

Страница 39: ...ing the dimples down and along the incline channels until they seat at the end of the channels Figure 29 Flexible Vent Adaptor Figure 30 Flexible Vent Apply ONLY MIL PAC BLACK HIGH TEMPERATURE SEALANT...

Страница 40: ...e flexible vent NOTE Ensure that the flexible vent is properly routed to provide the required clearance Do NOT allow the flexible vent to bend in a radius tighter than 5 127 mm Figure 30 Page 39 Place...

Страница 41: ...pre wired at the factory for the Electronic wiring 2000 series Electronic Wiring DRL2000 series One of the following optional controls must be used ON OFF Wall Switch Thermostat or Remote Control See...

Страница 42: ...an umbilical cord wiring harness Install a junction box not provided on the wall adjacent to the appliance within reach of the remote system umbilical cord wiring harness 7 After the wiring is complet...

Страница 43: ...ectronic Gas Valve DRL3500 Series Pilot Tube COLOR CODE B BLACK BB BROWN W BLACK STRIPE BG BROWN W GREEN STRIPE BL BLUE BR BROWN G GREEN GY GRAY O ORANGE R RED W WHITE Y YELLOW Spark Electrode Flame S...

Страница 44: ...ther tighten or refasten the leaking connection and then retest as described above 3 When the gas lines are tested and leak free rinse off the leak testing solution 13 Connect the Gas Line All codes r...

Страница 45: ...it will take a few minutes for the gas line to purge itself of air When purged the pilot and burner will light and operate as indicated Subsequent lighting of the fireplace will not require purging I...

Страница 46: ...e following fireplace functions Primary burner ON OFF Flame height and heat output adjustment six levels The receiver accepts commands via radio frequency from the transmitter and does not require lin...

Страница 47: ...ooting black tip the air shutter opening may need to be adjusted If the air shutter opening is closed too far sooting may develop Sooting is indicated by black puffs developing at the tips of very lon...

Страница 48: ...up to decrease it The rod is located in the lower control compartment Position the air shutter to the factory setting Table 25 2 Light the fireplace Follow the lighting procedure on the lighting label...

Страница 49: ...f left hand side of unit and remove 2 screws or remove the barrier assembly and remove the front lower access panel 2 screws B If unit is installed with optional facade remove facade and follow Step A...

Страница 50: ...bels at all fireplace operation and control points Page 51 NOTE The installer MUST ensure these warnings are properly attached during installation The warning labels are a critical means of informing...

Страница 51: ...ollez l tiquette sur la surface de la plaque de l interrupteur mural qui contr le le foyer Figure A ou du thermostat mural Choisissez la langue qui est principalement parl e dans la r sidence du propr...

Страница 52: ...of Flashing 77L79 SV4 5FA 1 12 to 7 12 Adjustable Flashing 77L80 SV4 5FB 7 12 to 12 12 Adjustable Flashing 77L81 SV4 5SC6 Storm Collar 6 pack H6183 SV4 5HF5 Firestop Spacer 5 rigid H6184 SF4 5HF5 Fire...

Страница 53: ...ion for flex with 24 610 mm of compressed flex vent see 750204M 94L07 SFKIT36SS Small Square Termination for flex with 36 914 mm of compressed flex vent see 750204M 94L08 SFKIT48SS SmallSquareTerminat...

Страница 54: ...tte trousse L installation n est pas ad quate ni compl te tant que le bon fonctionnement de l appareil converti n a pas t v rifi selon les instructions du fabricant fournies avec la trousse Le fournis...

Страница 55: ...by carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes NOTE Do not place furniture or othe...

Страница 56: ...tato de pared quecontrolalachimenea verifiquequeelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta...

Страница 57: ...smoke detector Do not operate the blower during the burn in period A white film may develop on the glass front during the first few fires as part of the burn in period The glass should be kept clean...

Страница 58: ...vent sooting and performance IMPORTANT NOTE Not remove sticker until media is completely placed Verify pilot flame is not obstructed and the 1 2 clearance from pilot cover to burner is maintained Ensu...

Страница 59: ...over Make certain not to drop glass down in between pilot cover and burner Figure 48 NOTE As crushed glass varies in size and installation it may be necessary to add or remove small amounts of glass t...

Страница 60: ...talled AVERTISSEMENT Une barri re con ue pour r duire le risque de br lure par le hublot chaude est fournie avec l appareil et doit tre install WARNING Do not operate appliance with the glass front re...

Страница 61: ...force When installed properly the bottom of the door should not have interference with the fireplace in order to close If it does remove the door and inspect the door gasket to ensure it is even and n...

Страница 62: ...ing system components However more frequent periodic inspections and cleanings should be performed by the homeowner NOTE Prior to the first use of the fireplace and each burn season and periodically d...

Страница 63: ...dia Vacuum out any foreign matter on the burner e g lint carbon etc Ensure the burner ports are free of debris NOTE Improper positioning of logs media can create carbon build up and will alter the per...

Страница 64: ...ction Look for any signs of dislocation of the vent components Appliance Inspection Qualified Service Technician Perform the appropriate appliance inspection procedure detailed in this manual Maintena...

Страница 65: ...inor scratches and discoloration of the fireplace black painted surfaces with the touch up paint kits PA I N T Glass Media Kits 5 lb Bag Cat No Model Description H8412 CRSHGL RBLK Reflective Black H84...

Страница 66: ...120 OFF minutes Wall surface mounted Connects to wall switch wire Perfect for rental and resort applications Wall Switch Countdown Timer Cat No Model No Description H8863 WS S TMR Wall Switch Remote S...

Страница 67: ...A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE OPERATING smell all around the appliance area for gas Be sure...

Страница 68: ...pe suivante 8 Mettez l appareil sous tension 9 Placez l interrupteur du r cepteur en position REMOTE 10 Appuyez sur le bouton ON OFF pour s lectionner ON 11 Ajustez le thermostat sur la t l commande l...

Страница 69: ...y gas control which has been under water Electronic Gas Control Valve SIT Electronic Pilot Assembly 3 Turn off all electric power to the appliance if service is to be performed Note The control may ha...

Страница 70: ...peut avoir une batterie de secours installer les batteries au besoin 8 Placez l interrupteur du r cepteur en position REMOTE ou l interrupteur mural en position ON 9 Si applicable Appuyez sur le bouto...

Страница 71: ...r call a service technician if required e Unit is not receiving power Replace unit battery backup 3 The main Burner comes on but then goes out a Fireplace has not established proper draft Switch CPI I...

Страница 72: ...es Electronic DRL2000 series 19 19 14 13 15 17 16 18 Cat No Fireplace Model Shipping Wt Shipping Vol F4182 DRL2035TEN 101 lb 9 3 cu ft F4183 DRL3535TEN 101 lb 9 3 cu ft F4186 DRL2045TEN 126 lb 11 9 cu...

Страница 73: ...432 1 F4433 1 8 Lintel F3656 1 F3658 1 F3656 1 F3658 1 F4429 1 F4429 1 9 Firebox Floor Front F4264 1 F4265 1 F4264 1 F4265 1 F4435 1 F4435 1 10 Convection Hood F3653 1 F3655 1 F3653 1 F3655 1 F4430 1...

Страница 74: ...er for backup batteries Proflame I H8803 1 H8803 1 H8803 1 19 Gas Flex Line Connector with Shutoff 93L32 1 93L32 1 93L32 1 93L32 1 93L32 1 93L32 1 Pilot Assembly SIT Natural Gas H7268 1 H7268 1 H7268...

Страница 75: ...or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damage...

Страница 76: ...er Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products IHP reserves the right to make changes at any time without notice in design materials specifications p...

Отзывы: