Installation
900994-00K, 07/2021
Innovative Hearth Products
DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces
19
FRAMING AND FINISHING
Continued
Table 12 - Fireplace Framing Dimensions For HeatFlo Installations - Flush Wall & Recessed Wall Pocket
Framing Dimensions - Inches (millimeters)
A
B
C
D
E*
F*
G
H*
45” Models
45-7/8 (1165)
18 (458)
29 (737)
3-1/2 (89)
81-1/2 (2070)
1-1/2 (38)
43-1/2 (1105)
5-1/8 (130)
55” Models
55-7/8 (1420)
18 (458)
29 (737)
3-1/2 (89)
81-1/2 (2070)
1-1/2 (38)
53-1/2 (1359)
5-1/8 (130)
with HeatFlo Kit
for Flush Wall
with HeatFlo Kit
for Recessed Wall Pocket
E*
B
A
G
H
C
F*
F*
D
A
B
E*
G
H
C
with HeatFlo Kit
for Flush Wall
with HeatFlo Kit
for Recessed Wall Pocket
E*
B
A
G
H
C
F*
F*
D
A
B
E*
G
H
C
with HeatFlo Kit
for Flush Wall
with HeatFlo Kit
for Recessed Wall Pocket
NOTE
: Unit must be installed a minimum of 6” off floor if the optional facade is to be installed.
TVs should not be used in situations where the actual TV temperature exceeds the manufacturer’s technical specification. Contact the TV manufacturer
directly if you cannot locate this information or have questions regarding this information.
D* Maximum allowable depth
E* Minimum height from appliance base to ceiling
F* Minimum distance from framed opening to ceiling
f i r e - p a r t s . c o m