Installation
900994-00K, 07/2021
Innovative Hearth Products
DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces
41
13.
Complete the Field Wiring
CAUTION
The ground supply lead must be connected to the wire attached to the green ground screw
located on the outlet box (see wiring diagrams). Failure to do so will result in a potential
safety hazard. The appliance must be electrically grounded in accordance with local codes
or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70—latest edition
(in Canada, the current CSA C22.1 Canadian Electrical Code).
CAUTION
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
ATTENTION
Au moment de l’entretien des commandes, étiquetez tous les fils avant de les débrancher.
Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
Green
Ground
Screw
Black
Hot Side of
Receptacle
Tab Intact
Tab
Broken
Green
White
Neutral
Side of
Receptacle
120 VAC - Black
Neutral - White
Ground - Green
J-BOX / RECEPTACLE
WIRING 120V, 60HZ, 1PH
Junction Box
Field Wired
Factory Wired
(Power
Supply
Unswitched)
Figure 31 - Wiring Diagram—Junction Box
Red
Verify proper operation after servicing.
S’assurer que l’appareil fonctionne adéquatement une fois l’entretien terminé.
The gas valve is set in place and pre-wired at the factory for the Electronic wiring 2000 series.
Electronic Wiring DRL2000 series
One of the following optional controls must be used:
• ON/OFF Wall Switch,
• Thermostat, or
• Remote Control
See the
Operation
section on
Page 55
for more details.
NOTE:
Electronic models must be connected to the main power supply.
1.
Route a 3-wire, 120 Vac, 60 Hz, 1 ph power supply to the fireplace junction box.
2.
Remove the electrical inlet cover plate from the side of the unit by removing the plate’s securing screws
(
Table 11,
Page 18
)
.
3.
If unit is not supplied with a strain relief, remove the cover plate knockout. Then, feed the power supply wire through
the knockout opening and into the unit junction box.
4.
Connect the black power supply wire to the lower outlet’s red pigtail lead
(
Figures 31-33, Pages 41-43
)
. Connect
the white power supply wire to the outlet’s common terminal.
5.
Connect the ground supply wire to the pigtail lead attached to the outlet’s green ground screw. Restrain the inlet
power lead per NEC or local codes.
6.
If a wall-mounted ON/OFF control, High/Low switch, or thermostat is to be used, mount it in a convenient location on a wall
near the fireplace.
7.
If an optional control is to be used, wire it in the low voltage circuit
(
Figures 32-33, Pages 42-43
)
.
NOTE:
The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit and
the other end of each conductor placed loose inside the bottom compartment.
8.
After the wiring is complete, replace the cover plate.