Installation
900994-00K, 07/2021
Innovative Hearth Products
DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces
15
MINIMUM CLEARANCES TO COMBUSTIBLES
Fireplace And Vent Clearances
The fireplace is approved with zero clearance to combustible materials
on all sides
(
Table 8
)
, with the following exception: The unit may not
be recessed (allowance made for mantel legs / side trim in
Figure 5C,
Page 16
)
. When the unit is installed with one side flush with a wall, the
wall on the other side of the unit must not extend beyond the front edge
of the unit
(
Figure 5C, Page 16
)
.
The fireplace must be mounted on a fully supported base extending
the full width and depth of the unit. The fireplace may be located on
or near conventional construction materials. However, if installed on
combustible materials, such as carpeting, vinyl tile or other combustible
material other than wood flooring, the appliance shall be installed on a
metal or wood panel extending the full width and depth of the appliance.
Table 8 - Minimum Clearances *
Back ***
1/2” (13 mm) to wrapper
0” (0 mm) to Spacers
Sides
1/2” (13 mm) to wrapper
0” (0 mm) to Spacers **
Top Standoffs
0” (0 mm) to top standoffs
Floor
0” (0 mm) ***
From Bottom of Unit to Ceiling
52” (1321 mm)
Vent
3” (77 mm)—Top *
1” (26 mm)—Sides and Bottom
Front Service Clearance—
clearance immediately in front of
viewing area(s)
36” (914 mm)
* 3” (77 mm) above any horizontal/inclined vent component.
** See Page 23 for clearance requirements to the nailing flange
located at each side of the unit and any screw heads adjacent to it.
*** 6” (153 mm) if optional facade is used.
Hearth Extension
A hearth extension is not required with this fireplace. Any hearth extension used is for appearance only and does not have to conform to
standard hearth extension installation requirements.
Shelf Height
To provide for the lowest possible shelf surface, the venting attached to the top vent should be routed in a way to minimize obstructions to
the space above the fireplace. Do not insulate the space between the fireplace and the area above it
(
Table 9
)
. The minimum height from
the base of the fireplace to the underside of combustible materials used to construct a utility shelf in this fashion is shown in
Table 9
.
Table 9- Combustible Shelf Height—Top Vent
Model
Top Vent with one 90° Elbow *
(55” models require 12” of vertical rise directly off unit)
Shelf Height
(see table)
The unit is
required to be a
minimum of 6”
off floor to install
optional facade.
Secure Vent
®
(using rigid elbow)
Secure Flex
®
(using flex elbow)
35” Models
47” (1194 mm)
49” (1245 mm)
45” Models
52” (1321 mm)
54” (1372 mm)
55” Models
62” (1575 mm)
64” (1626 mm)
CLEARANCES TO COMBUSTIBLES MUST BE MAINTAINED
:
No combustible materials or insulation is permitted in the shaded area
between the appliance and the shelf above it.
WARNING
: CRITICAL INSTALLATION INFORMATION THAT IF NOT FOL-
LOWED CAN RESULT IN A SAFETY HAZARD!