background image

General Information

900994-00K, 07/2021

Innovative Hearth Products
DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces

5

Important Safety Informa-

tion

1. WARNING: Do not operate appliance 

with the glass front removed, cracked 
or broken. 

2. Do not use this appliance if any part 

has  been  under  water.  Immediately 
call a qualified service technician to 
inspect the appliance and to replace 
any  part  of  the  control  system  and 
any gas control which has been under 
water.

3. Due to high temperatures, the appli-

ance  should  be  located  out  of  traffic 
and away from furniture and draperies.

4. Children and adults should be alerted 

to  the  hazards  of  high  surface  tem-
perature and should stay away to avoid 
burns or clothing ignition. 

5. Clothing or other flammable material 

should  not  be  placed  on  or  near  the 
appliance.

6. Young  children  should  be  carefully 

supervised when they are in the same 
room  as  the  appliance.  Toddlers, 
young children, and others may be sus-
ceptible  to  accidental  contact  burns. 
A  physical  barrier  is  recommended 
if there are at-risk individuals in the 
house. To restrict access to a fireplace 
or stove, install an adjustable safety 
gate to keep toddlers, young children, 
and other at-risk individuals out of the 
room and away from hot surfaces.

7. Any  safety  screen,  guard  or  barrier 

removed  for  servicing  an  appliance 
must  be  replaced  prior  to  operating 
the appliance.

8. Installation and repair should be done 

by a qualified service person. The ap-
pliance should be inspected before use 
and at least annually by a professional 
service person. More frequent clean-
ing may be required due to excessive 
lint from carpeting, bedding material, 
et cetera. It is imperative that control 
compartments, burners, and circulat-
ing air passageways of the appliance 
be  kept  clean.  See  maintenance  in-
structions on 

Page 62

.

L’information de sûreté 

importante

1.  AVERTISSEMENT. Ne pas utiliser l’appareil 

si le panneau frontal en verre n’est pas en 

place, est craqué ou brisé. 

2.  Ne pas se servir de cet appareil s’il a été 

plongé  dans  l’eau,  même  partiellement. 

Faire inspecter l'appareil par un technicien 

qualifié et remplacer toute partie du systéme 

de contrôle et toute commande qui ont été 

plongées dans l'eau.

3.  En  raison  des  températures  élevées, 

l’appareil devrait être installé dans un en-

droit où il y a peu de circulation et loin du 

mobilier et des tentures.

4.  Les  enfants  et  les  adultes  devraient  être 

informés des dangers que posent les tem-

pératures de surface élevées et se tenir à 

distance afin d’éviter des brûlures ou que 

leurs vêtements ne s’enflamment.

5.  On  ne  devrait  pas  placer  de  vêtements 

ni  d’autres  matières  inflammables  sur 

l’appareil ni à proximité.

6.  Les jeunes enfants devraient être surveillés 

étroitement  lorsqu’ils  se  trouvent  dans  la 

même pièce que l’appareil. Les tout petits, 

les jeunes enfants ou les adultes peuvent 

subir des brûlures s’ils viennent en contact 

avec la surface chaude. Il est recommandé 

d’installer  une  barrière  physique  si  des 

personnes  à  risques  habitent  la  maison. 

Pour empêcher l’accès à un foyer ou à un 

poêle, installez une barrière de sécurité ; 

cette mesure empêchera les tout petits, les 

jeunes enfants et toute autre personne à ris-

que d’avoir accès à la pièce et aux surfaces 

chaudes.

7.  Tout  écran  ou  protecteur  retiré  pour  per-

mettre  l’entretien  de  l’appareil  doit  être 

remis en place avant de mettre l’appareil 

en marche.

8.  L’installation  et  la  réparation  devrait  être 

confiées à un technicien qualifié. L’appareil 

devrait faire l’objet d’une inspection par un 

technicien professionnel avant d’être utilisé 

et au moins une fois l’an par la suite. Des 

nettoyages  plus  fréquents  peuvent  être 

nécessaires si les tapis, la literie, et cetera 

produisent une quantité importante de pous-

sière. Il est essentiel que les compartiments 

abritant les commandes, les brûleurs et les 

conduits  de  circulation  d’air  de  l’appareil 

soient tenus propres. Voyez les instructions 

d’entretien à la 

Page 62

.

Información importante de 

seguridad

1.  ADVERTENCIA: No opere el artefacto con el 

frente de vidrio quitado, agrietado o roto.  

2.  No use este artefacto si alguna de sus partes 

ha  estado  bajo  agua.  Llame  de  inmediato 
a  un  técnico  de  servicio  calificado  para 
que  inspeccione  el  artefacto  y  reemplace 
cualquier  parte  del  sistema  de  control  y 
cualquier  control  de  gas  que  haya  estado 
bajo agua.

3.  Debido a las altas temperaturas, el artefacto 

debe situarse fuera de las áreas de tráfico y 
lejos del mobiliario y cortinas.

4.  Se debe alertar a los niños y adultos sobre 

los peligros de las altas temperaturas en la 
superficie y que se mantengan alejados para 
evitar quemaduras o ignición de la ropa. 

5.  No debe colocarse ropa u otros materiales 

inflamables sobre y cerca del artefacto.

6.  Se  debe  supervisar  de  cerca  a  los  niños 

cuando  estén  en  el  mismo  cuarto  que  el 
artefacto. Los niños pequeños, los jóvenes 
y  otras  personas  pueden  ser  susceptibles 
a quemaduras por contacto accidental. Se 
recomienda instalar una barrera física si hay 
personas en riesgo en la casa. Para restringir 
el acceso a una chimenea o estufa, instale 
una  puerta  de  seguridad  ajustable  para 
mantener a los niños pequeños, jóvenes y 
otras personas en riesgo fuera del cuarto y 
lejos de las superficies calientes.

7.  Cualquier malla o resguardo de seguridad 

quitado para dar servicio a un artefacto, debe 
reinstalarse antes de operar el artefacto.

8.  Una  persona  de  servicio  competente  debe 

realizar  la  instalación  y  reparación.  Una 
persona  de  servicio  profesional  debe 
inspeccionar  el  artefacto  antes  de  usar  al 
menos una vez por año. Se puede requerir 
limpieza más frecuente debido a la pelusa 
excesiva  del  alfombrado,  del  material  de 
cobijas,  etc.  Es  imprescindible  mantener 
limpios los compartimientos de control, los 
quemadores y los pasajes de circulación del 
aire del artefacto. Ver las instrucciones de 
mantenimiento en la 

página 62

.

IMPORTANT SAFETY INFORMATION

[English]

[French]

[Spanish]

f i r e - p a r t s . c o m

Содержание DRL2000 Series

Страница 1: ...un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoivent treassur spar un installateur ou...

Страница 2: ...tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre chaude et doit tre install pour la protection Des enfants et Des personnes risques Vea el volante...

Страница 3: ...toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidr...

Страница 4: ...ion Preparation 17 Installation Installation Sequence 17 Construct the Fireplace Framing 17 Prepare the Fireplace Top Spacers 21 Route the Gas Supply Line to the Fireplace 21 Installing Header Shield...

Страница 5: ...bir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po...

Страница 6: ...rous Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning CARBON MONOXIDE POISONING Early signs of carbon monoxide po...

Страница 7: ...ccessibility clearance for service and proper operation Never obstruct the front openings of the appliance These appliances are designed as supplemental heaters Therefore it is advisable to have an al...

Страница 8: ...a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etcetera It is imperative that control compartment burners and circulating a...

Страница 9: ...tructions 900949 00 provided with this appliance Table 1 Input Rate BTU HR Gas Valves Burner Model Natural Gas Propane LP Gas Field Converted High Rate Low Rate High Rate Low Rate DRL2035 15 000 13 00...

Страница 10: ...diminish 4 for every 1 000 ft of altitude IN CANADA CAN CGA 2 17 M91 HIGH ALTITUDE THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURER S AUTHORIZED REPRESENTATIVE IN ACCORDANCE WITH THE REQUIREMENT...

Страница 11: ...noxide detector must comply with NFPA 720 be ANSI UL 2034 listed and be ISA certified A metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum h...

Страница 12: ...urniture and draperies En raison des temp ratures lev es l appareil devrait tre install dans un endroit o il y a peu de circulation et loin du mobilier et des tentures The location should also be free...

Страница 13: ...to 14 12 5 0 ft 1 52 m 14 12 to 16 12 6 0 ft 1 83 m 16 12 to 18 12 7 0 ft 2 13 m 18 12 to 20 12 7 5 ft 2 29 m 20 12 to 21 12 8 0 ft 2 44 m 12 X Roof pitch is X 12 2 ft minimum 2 ft minimum Lowest disc...

Страница 14: ...onmechanical air supply inlet to building or the combustion air inlet to any other fireplace 6 150 mm for fireplaces 10 000 Btu h 3 kW 9 230 mm for fireplaces 10 000 Btu h 3 kW and 50 000 Btu h 15 kW...

Страница 15: ...m 3 77 mm above any horizontal inclined vent component See Page 23 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it 6 153 mm if opti...

Страница 16: ...nimum clearance requirements include any projections such as shelves window sills mantels etc above the fireplace NOTE To avoid heat related finish damage we recommend the use of high temperature pain...

Страница 17: ...l Vent System Page 23 9 Install the Vent Restrictor if necessary Page 23 10 Connecting the Vent Pipe Page 25 11 Install the Vent System Page 28 Electrical Connection 12 Complete the Field Wiring Page...

Страница 18: ...1 2 547 29 737 42 1067 18 458 N A A Minimum opening size additional 1 8 per side is recommended G For installations with 12 section directly off unit then elbow NOTE Framing specifications do NOT app...

Страница 19: ...ith HeatFlo Kit for Recessed Wall Pocket E B A G H C F F D A B E G H C with HeatFlo Kit for Flush Wall with HeatFlo Kit for Recessed Wall Pocket E B A G H C F F D A B E G H C with HeatFlo Kit for Flus...

Страница 20: ...replace Ceiling Wall HeatFlo Vent Opening B C A Min 76 1 930 m Max 20 ft 6 096 m Base of Fireplace Figure 6A Dimensions for Television TV Installed Above Fireplace on a Recessed Wall Pocket Television...

Страница 21: ...kets NOTE DRL3535TEN and DRL3545TEN models require a 4 75 non combustible fireboard provided while DRL2035TEN and DRL2045TEN models require a 2 75 non combustible board provided The gas supply line sh...

Страница 22: ...Step 1 Remove screw holding standoff to firebox bend to 4 tall as seen above and attach screw Step 2 Install the header shield by sliding it into the slot in the standoffs Step 3 Fireboard standoff ca...

Страница 23: ...oved vent components See Pages 28 31 vertical and Pages 34 38 horizontal NOTE This fireplace must be vented directly to the outside WARNING The vent system may not service multiple appliances and must...

Страница 24: ...rea raised Base Vent Restrictor Base Vent Restrictor Wing With break away raised Minimal Restrictor Vent Restrictor with Vertical Terminations When vertically terminating the vent system through the r...

Страница 25: ...equired length The SV4 5LA Telescopic Vent Section has an effective length of from 1 1 2 to 7 38 to 178 mm The SV4 5LA is fitted with a locking inclined channel end identical to a normal vent section...

Страница 26: ...ctions in Figure 18 NOTE Same installation applies if installed in a corner STEP 1 Locate the two 2 flat elbow shields STEP 2 Bend the three 3 tabs 90 degrees as shown below STEP 3 Attach the two 2 sh...

Страница 27: ...5 38 75 0 0 0 0 10 10 69 5 75 0 0 0 2 0 2 475 5 39 625 0 1 0 0 10 11 73 5 6 125 1 0 0 2 0 3 480 40 1 1 0 0 10 12 79 5 6 625 0 1 0 2 0 3 492 41 1 0 1 0 10 12 81 6 75 0 0 0 1 1 2 499 5 41 625 0 0 0 1 10...

Страница 28: ...figures Secure Flex pipe may also be used A table summarizes each configuration s minimum and maximum vertical and horizontal length parameters for a variety of applications 1 Refer to Figure 24 and T...

Страница 29: ...living space above the ceiling level the firestop spacer must be installed on the bottom side of the ceiling If attic space is above the ceiling the firestop spacer must be installed on the top side o...

Страница 30: ...op and both sides of the flashing with waterproof caulking The flashing must overlap the roofing material along the bottom 11 Install the storm collar Install the storm collar supplied with the flashi...

Страница 31: ...HF Secure Flex firestop spacer must be used anytime vent pipe passes through a combustible wall NOTE Two 2 45 elbows may be used in place of one 1 90 elbow The same rise to run ratios as shown in the...

Страница 32: ...f H horizontal run up to a maximum horizontal run of 25 ft Minimum 6 ft and maximum of 60 ft of vertical venting Table 18 Top Vent Three Elbows H H1 Maximum V Minimum feet meters feet meters 5 1 524 E...

Страница 33: ...t Length on Pages 25 27 for more information Plan the venting so that a joint does not occur in the ceiling or roof joists Allow for elbows Figure 18 Page 26 Maintain clearances to combustibles equal...

Страница 34: ...the exterior side of the framing long side up with the 3 spacer clearance at the top Figure 27 Page 33 and nail into place This Wall Heatshield shall be installed using the provided burn screws on th...

Страница 35: ...0K81 or high temperature silicone Figure 28 Venting Connection and Exterior Wall Recessing of the Horizontal Termination Use silicone caulking to seal the top and sides of the termination up to the un...

Страница 36: ...able all the way to at or near level Use a carpenter s level to measure from a constant surface and adjust the support straps as necessary NOTE SV4 5VF Secure Vent SF4 5VF Secure Flex firestop spacer...

Страница 37: ...ne Foot Vent Section Required When using Secure Flex use ceiling firestop spacer SF4 5VF When using Secure Flex use wall firestop spacer SF4 5HF Wall firestop spacer SV4 5HF Ceiling firestop spacer SV...

Страница 38: ...hows a 1 V to 5 H ratio For every 1 ft of V vertical you are allowed 5 ft of H horizontal run up to a maximum horizontal run of 20 ft 6 096 m NOTE The Wall Heatshield provided shall be installed per i...

Страница 39: ...ing the dimples down and along the incline channels until they seat at the end of the channels Figure 29 Flexible Vent Adaptor Figure 30 Flexible Vent Apply ONLY MIL PAC BLACK HIGH TEMPERATURE SEALANT...

Страница 40: ...e flexible vent NOTE Ensure that the flexible vent is properly routed to provide the required clearance Do NOT allow the flexible vent to bend in a radius tighter than 5 127 mm Figure 30 Page 39 Place...

Страница 41: ...pre wired at the factory for the Electronic wiring 2000 series Electronic Wiring DRL2000 series One of the following optional controls must be used ON OFF Wall Switch Thermostat or Remote Control See...

Страница 42: ...an umbilical cord wiring harness Install a junction box not provided on the wall adjacent to the appliance within reach of the remote system umbilical cord wiring harness 7 After the wiring is complet...

Страница 43: ...ectronic Gas Valve DRL3500 Series Pilot Tube COLOR CODE B BLACK BB BROWN W BLACK STRIPE BG BROWN W GREEN STRIPE BL BLUE BR BROWN G GREEN GY GRAY O ORANGE R RED W WHITE Y YELLOW Spark Electrode Flame S...

Страница 44: ...ther tighten or refasten the leaking connection and then retest as described above 3 When the gas lines are tested and leak free rinse off the leak testing solution 13 Connect the Gas Line All codes r...

Страница 45: ...it will take a few minutes for the gas line to purge itself of air When purged the pilot and burner will light and operate as indicated Subsequent lighting of the fireplace will not require purging I...

Страница 46: ...e following fireplace functions Primary burner ON OFF Flame height and heat output adjustment six levels The receiver accepts commands via radio frequency from the transmitter and does not require lin...

Страница 47: ...ooting black tip the air shutter opening may need to be adjusted If the air shutter opening is closed too far sooting may develop Sooting is indicated by black puffs developing at the tips of very lon...

Страница 48: ...up to decrease it The rod is located in the lower control compartment Position the air shutter to the factory setting Table 25 2 Light the fireplace Follow the lighting procedure on the lighting label...

Страница 49: ...f left hand side of unit and remove 2 screws or remove the barrier assembly and remove the front lower access panel 2 screws B If unit is installed with optional facade remove facade and follow Step A...

Страница 50: ...bels at all fireplace operation and control points Page 51 NOTE The installer MUST ensure these warnings are properly attached during installation The warning labels are a critical means of informing...

Страница 51: ...ollez l tiquette sur la surface de la plaque de l interrupteur mural qui contr le le foyer Figure A ou du thermostat mural Choisissez la langue qui est principalement parl e dans la r sidence du propr...

Страница 52: ...of Flashing 77L79 SV4 5FA 1 12 to 7 12 Adjustable Flashing 77L80 SV4 5FB 7 12 to 12 12 Adjustable Flashing 77L81 SV4 5SC6 Storm Collar 6 pack H6183 SV4 5HF5 Firestop Spacer 5 rigid H6184 SF4 5HF5 Fire...

Страница 53: ...ion for flex with 24 610 mm of compressed flex vent see 750204M 94L07 SFKIT36SS Small Square Termination for flex with 36 914 mm of compressed flex vent see 750204M 94L08 SFKIT48SS SmallSquareTerminat...

Страница 54: ...tte trousse L installation n est pas ad quate ni compl te tant que le bon fonctionnement de l appareil converti n a pas t v rifi selon les instructions du fabricant fournies avec la trousse Le fournis...

Страница 55: ...by carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes NOTE Do not place furniture or othe...

Страница 56: ...tato de pared quecontrolalachimenea verifiquequeelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta...

Страница 57: ...smoke detector Do not operate the blower during the burn in period A white film may develop on the glass front during the first few fires as part of the burn in period The glass should be kept clean...

Страница 58: ...vent sooting and performance IMPORTANT NOTE Not remove sticker until media is completely placed Verify pilot flame is not obstructed and the 1 2 clearance from pilot cover to burner is maintained Ensu...

Страница 59: ...over Make certain not to drop glass down in between pilot cover and burner Figure 48 NOTE As crushed glass varies in size and installation it may be necessary to add or remove small amounts of glass t...

Страница 60: ...talled AVERTISSEMENT Une barri re con ue pour r duire le risque de br lure par le hublot chaude est fournie avec l appareil et doit tre install WARNING Do not operate appliance with the glass front re...

Страница 61: ...force When installed properly the bottom of the door should not have interference with the fireplace in order to close If it does remove the door and inspect the door gasket to ensure it is even and n...

Страница 62: ...ing system components However more frequent periodic inspections and cleanings should be performed by the homeowner NOTE Prior to the first use of the fireplace and each burn season and periodically d...

Страница 63: ...dia Vacuum out any foreign matter on the burner e g lint carbon etc Ensure the burner ports are free of debris NOTE Improper positioning of logs media can create carbon build up and will alter the per...

Страница 64: ...ction Look for any signs of dislocation of the vent components Appliance Inspection Qualified Service Technician Perform the appropriate appliance inspection procedure detailed in this manual Maintena...

Страница 65: ...inor scratches and discoloration of the fireplace black painted surfaces with the touch up paint kits PA I N T Glass Media Kits 5 lb Bag Cat No Model Description H8412 CRSHGL RBLK Reflective Black H84...

Страница 66: ...120 OFF minutes Wall surface mounted Connects to wall switch wire Perfect for rental and resort applications Wall Switch Countdown Timer Cat No Model No Description H8863 WS S TMR Wall Switch Remote S...

Страница 67: ...A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE OPERATING smell all around the appliance area for gas Be sure...

Страница 68: ...pe suivante 8 Mettez l appareil sous tension 9 Placez l interrupteur du r cepteur en position REMOTE 10 Appuyez sur le bouton ON OFF pour s lectionner ON 11 Ajustez le thermostat sur la t l commande l...

Страница 69: ...y gas control which has been under water Electronic Gas Control Valve SIT Electronic Pilot Assembly 3 Turn off all electric power to the appliance if service is to be performed Note The control may ha...

Страница 70: ...peut avoir une batterie de secours installer les batteries au besoin 8 Placez l interrupteur du r cepteur en position REMOTE ou l interrupteur mural en position ON 9 Si applicable Appuyez sur le bouto...

Страница 71: ...r call a service technician if required e Unit is not receiving power Replace unit battery backup 3 The main Burner comes on but then goes out a Fireplace has not established proper draft Switch CPI I...

Страница 72: ...es Electronic DRL2000 series 19 19 14 13 15 17 16 18 Cat No Fireplace Model Shipping Wt Shipping Vol F4182 DRL2035TEN 101 lb 9 3 cu ft F4183 DRL3535TEN 101 lb 9 3 cu ft F4186 DRL2045TEN 126 lb 11 9 cu...

Страница 73: ...432 1 F4433 1 8 Lintel F3656 1 F3658 1 F3656 1 F3658 1 F4429 1 F4429 1 9 Firebox Floor Front F4264 1 F4265 1 F4264 1 F4265 1 F4435 1 F4435 1 10 Convection Hood F3653 1 F3655 1 F3653 1 F3655 1 F4430 1...

Страница 74: ...er for backup batteries Proflame I H8803 1 H8803 1 H8803 1 19 Gas Flex Line Connector with Shutoff 93L32 1 93L32 1 93L32 1 93L32 1 93L32 1 93L32 1 Pilot Assembly SIT Natural Gas H7268 1 H7268 1 H7268...

Страница 75: ...or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damage...

Страница 76: ...er Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products IHP reserves the right to make changes at any time without notice in design materials specifications p...

Отзывы: