background image

4

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

In Canada - CAN/CGA-2.17-M91 (R2009) (high 

altitude):

ThE CONVERSION ShALL BE CARRIED OUT 

BY A MANUFACTURER’S AUThORIZED REP-

RESENTATIVE, IN ACCORDANCE WITh ThE 

REQUIREMENTS OF ThE MANUFACTURER, 

PROVINCIAL OR TERRITORIAL AUThORITIES 

hAVING JURISDICTION AND IN ACCORDANCE 

WITh ThE REQUIREMENTS OF ThE CAN/CGA-

B149.1 OR CAN/CGA-B149.2 INSTALLATION 

CODES.

REQUIREMENTS FOR ThE COMMON-

WEALTh OF MASSAChUSETTS

These fireplaces are approved for installation in 

the US state of Massachusetts if the following 

additional requirements are met:

•  Install  this  appliance  in  accordance  with 

Massachusetts Rules and Regulations 248 

C.M.R. 

•  Installation and repair must be done by a 

plumber or gas fitter licensed in the Com

-

monwealth of Massachusetts.

•  The flexible gas line connector used shall 

not exceed 36 in. (92 centimeters) in length.

•  The individual manual shut-off must be a 

T-handle type valve. 

Massachusetts horizontal Vent Requirements 

In the Commonwealth of Massachusetts, hori-

zontal terminations installed less than seven 

(7) feet above the finished grade must comply 

with the following additional requirements:

•  A  hard  wired  carbon  monoxide  detector 

with an alarm and battery back-up must be 

installed on the floor level where the gas 

fireplace is installed. The carbon monoxide 

detector must comply with NFPA 720, be 

ANSI/UL 2034 listed and be ISA certified.

•  A metal or plastic identification plate must 

be permanently mounted to the exterior of 

the building at a minimum height of eight (8) 

feet above grade and be directly in line with 

the horizontal termination. The sign must 

read, in print size no less than one-half (1/2) 

inch in size, GAS VENT DIRECTLY BELOW. 

KEEP CLEAR OF ALL OBSTRUCTIONS.

Gas Valve Diagram

See Figure 1 for gas valve diagram.

Figure 1 - SIT Electronic Gas Valve

Wire

(From DFC Wire 

harness)

Pressure 

Regulator 

Tower

Yellow Ground Wire

(From DFC Wire 

harness)

Green Wire

(From DFC Wire 

harness)

Inlet (In) Test Port

Manifold (Out) 

Test Port

Connect GTMS 

Wire harness

Main Gas Inlet 

3/8" NPT

Test gauge connections are provided on the front 

of the gas control valve; identified IN for the inlet 

and OUT for the manifold side (see 

Figure 1).

Orifice Sizes - Sea Level To high Altitude

These appliances are tested and approved for 

installation at elevations of 0 - 4500 ft (0 - 1370 

m) above sea level, using the standard burner 

orifice sizes (marked with an "*" in 

Table 4)

For elevations above 4500 ft, contact your gas 

supplier or qualified service technician.

Deration - At  higher  elevations,  the  amount 

of BTU fuel value delivered must be reduced 

by either:

•   Using gas that has been derated by the gas 

company. 

•   Changing the burner orifice to a smaller size 

as regulated by the local Authorities Having 

Jurisdiction and by the (USA) National Fuel 

Gas  Code  NFPA  54/ANSI  Z223.1  -  latest 

edition, or in Canada, the CAN/CGA-B149.1 

code - latest edition.

Install the appliance according to the regulations 

of the local authorities having jurisdiction, and 

the (USA) National Fuel Gas Code NFPA 54 / 

ANSI Z223.1 - latest edition, 

or (Canada) CAN/CGA-B149.1 - latest edition.

NOTE: Flame appearance will diminish 4% 

per one thousand feet of altitude.

The appliance and its appliance main gas 

valve must be disconnected from the gas 

supply piping system during any pressure 

testing of that system at test pressures 

in 

excess of 1/2 psi (3.5 kPa).

The appliance must be isolated from the gas 

supply piping system by closing its equipment 

shutoff valve during any pressure testing of 

the gas supply piping system at test pres-

sures 

equal to or less than 1/2 psi (3.5 kPa).

PURGE CYCLE

This is a power vented fireplace that 

requires household electrical power 

to operate. It will not operate during 

a power failure. When the fireplace 

is turned off, the exhaust blower will 

continue to operate for approximately 

fifteen (15) seconds after shutdown 

to expel the exhaust gases from the 

venting system.

Burner Orifice Size 

Elevation 0 - 4500 ft (0 - 1370 m)

Model

Orifice Size / Catalog Number

40 in.

0.125" (1/8") * H7924 •

45 in.

0.136" (#29) * H8141 •

Table 4

* Standard size installed at factory

•  Part /Cat. Number

INNOVATIVE HEARTH PRODUCTS  •  POWER VENT DV GAS FIREPLACES  (DRT63__TYN / DRC63__TYN)  •  INSTALLATION INSTRUCTIONS

Gas Pressure - All Models 

Tables 2 and 3

 

show the appliance inlet and 

manifold gas pressure requirements.

Inlet Gas Supply Pressure

Minimum

Maximum

5.5" WC

(1.37 kPa)

10.5" WC

(2.62 kPa)

Table 2

Manifold Gas Supply Pressure

Low

high

1.6" WC

(.40 kPa)

3.5" WC

(.87 kPa)

Table 3

Содержание DRC6345TYNDRC6340TYN

Страница 1: ...E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y TOUCHER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNC...

Страница 2: ...peration Page 21 Step 9 Installing Logs Page 22 Step 10 Install Remove Glass Door Assembly Page 24 Step11 Burner Adjustments Page 24 Finishing Requirements Page 26 Step 12 Attaching Safety in Operatio...

Страница 3: ...WER VENT DV GAS FIREPLACES DRT63__TYN DRC63__TYN INSTALLATION INSTRUCTIONS WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this...

Страница 4: ...let and OUT for the manifold side see Figure 1 Orifice Sizes Sea Level To High Altitude These appliances are tested and approved for installation at elevations of 0 4500 ft 0 1370 m above sea level us...

Страница 5: ...actured home in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition LOCATION In selecting the location the aesthetic and function...

Страница 6: ...ead combustible projection of 2 1 2 64 mm or less see Figure 3 For projections exceeding 2 1 2 64 mm see Figure 3 For additional vent location restrictions refer to Figure 4 on Page 7 INNOVATIVE HEART...

Страница 7: ...s 10 000 BTU hr 3kW and 100 000 BTU hr 30kW 36 91 cm for appliances 100 000 BTU hr 30kW 6 15 2 cm for appliances 10 000 BTU hr 3kW 9 23 cm for appliances 10 000 BTU hr 3kW and 50 000 BTU hr 15kW 12 30...

Страница 8: ...rated 175 F or higher on the underside of the mantel MINIMUM CLEARANCES TO COMBUSTIBLES Appliance And Vent Clearances The appliance is approved with zero clearance to combustible materials on all sid...

Страница 9: ...low for a minimum clearance to combustible framing members as shown in Table 5 on Page 8 If the appliance is to be elevated above floor level a solid continuous platform must be constructed below the...

Страница 10: ...el No A B C D E F G H J 40 in in 50 5 8 37 1 4 42 7 8 25 5 16 34 37 5 8 33 3 32 29 9 32 34 3 4 mm 1286 946 1089 643 864 956 840 744 883 45 in in 56 11 16 42 1 4 47 7 8 28 3 8 40 1 8 43 5 8 38 3 32 34...

Страница 11: ...8 59 1 8 41 7 8 mm 1286 2124 1502 1064 45 in in 56 3 4 89 7 8 63 1 2 44 7 8 mm 1441 2283 1613 1140 C Back wall of chase enclosure including any finishing materials D A B Figure 9 Corner Framing with...

Страница 12: ...Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or Canada CAN CGA B149 1 latest edition These fireplaces are designed tested and listed for operation and installation only with Secure Vent SV4 5 and...

Страница 13: ...1 0 8 4 0 4 1 1 0 0 0 1 1 1 2 9 4 1 4 1 0 1 0 0 1 2 1 5 9 9 4 5 2 6 1 4 0 0 0 1 0 1 1 1 4 0 5 2 4 1 0 0 1 0 1 2 1 5 1 1 5 5 2 6 2 4 0 0 0 0 1 1 1 1 5 0 2 5 5 7 3 3 4 0 2 0 1 1 1 4 1 1 3 5 5 2 4 4 0 2...

Страница 14: ...x 1 2 screw may be used at the joint butitisnotrequiredasthepipewillsecurely lock when twisted C Attachventcomponentstoeachother Other vent sections may be added to the previously installedsectioninac...

Страница 15: ...Secure Vent firestop spacer must be used anytime vent pipe passes through a combustible wall Maintain the horizontal inclined run in a straight slightly elevated plane approximately 1 4 per foot 20 mm...

Страница 16: ...vent sections in horizontal inclined run as described in Step E Install support straps every three feet 1914 mm along horizontal inclined vent runs using conventional plumber s tape see Figure 16 on P...

Страница 17: ...TE Centerline of Vent Piping is NOT the Same as the Centerline of the Frame Opening 6 to 48 Vent Section Telescopic vent section Elbow or Appliance Collar Base of Appliance 3 76 mm 1 25 4 mm Adaptor S...

Страница 18: ...fireplace to the newly installed junction box near the termination Ensure the cable is safety plated to prevent damage from framing nails and finish drywall screws Route it into the lower control com...

Страница 19: ...n it to fit within the junction box cover WARNING Crimp connectors may be used on stranded cables such as SJOT cable only Solid wire Romex must be connected per the National Electric Code NEC 70 lates...

Страница 20: ...t only be replaced as a complete unit as provided by the manufacturer Do not attempt to replace broken cracked or chipped glass separately INNOVATIVE HEARTH PRODUCTS POWER VENT DV GAS FIREPLACES DRT63...

Страница 21: ...ed above C When the gas lines are tested and leak free be sure to rinse off the leak testing solution D Re install the access plate making certain the gasket has not been damaged Figure 29 Fireplace R...

Страница 22: ...able and attractive flame pattern Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Logs get very h...

Страница 23: ...e And Push It Towards The Rear 3 2 4 1 6 5 7 Log Number Description 1 Log Center 2 Log Rear 3 Log Center Left 4 Log Center Right 5 Log Rear Top 6 Log Front Left 7 Log Front Center Table 6 Log Set Alig...

Страница 24: ...st be replaced prior to operating the appliance AVERTISSEMENT Tout cran ou pro tecteurretir pourpermettrel entretiende l appareil doit tre remis en place avant de mettre l appareil en marche Installin...

Страница 25: ...nstallation Leave the ON REMOTE OFF wall switch in the REMOTE position and turn the remote switch OFF Use the remote to adjust the flame height as desired CAUTION Soot will be produced if the air shut...

Страница 26: ...ed there are two methods of installation Combustible or noncombustible finish material may abut the front face of the fireplace and the floor panel see Figure 45 Combustible or noncombustible finish m...

Страница 27: ...ipalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour liminer la poussi re et les traces degraisseoud...

Страница 28: ...Section 77L72 SV4 5L24 24 610mm Vent Section 77L73 SV4 5L36 36 914mm Vent Section 77L74 SV4 5L48 48 1219mm Vent Section 77L75 SV4 5LA Telescopic Section 77L76 SV4 5E45 45 Degree Elbow 77L77 SV4 5E90 9...

Отзывы: