background image

NOTE: If installing the contemporary burner/floor kit, skip 

this step and instead refer to the instructions provided 

with the kit.

22

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

INNOVATIVE HEARTH PRODUCTS  •  POWER VENT DV GAS FIREPLACES  (DRT63__TYN / DRC63__TYN)  •  INSTALLATION INSTRUCTIONS

Step 1.

 Install the ceramic or porcelain panels per the instructions 

provided in kit.

Step 2.  Place volcanic stone around the burner (the entire bag of volcanic 

stone will NOT be used). DO NOT PLACE VOLCANIC STONE ON 

ThE BURNER

. See Figure 32.

Step 3.  Separate the glowing embers (rockwool) into pieces about the 

size of a quarter (Figure 33)

. Keep the pieces fluffed, not matted. 

Distribute these pieces over the burner as shown in Figure 34

Do not use more than is necessary. When properly positioned, 

the glowing embers will cover approximately 75% of the burner.

Step 4.

  Distribute the platinum embers over the burner as desired. Do 

not use more than is necessary.
NOTE: Excessive use of embers may result in sooting or poor 

flame. This appliance is provided with enough embers for 

several applications, do not use all that is in a new bag. For 

best glowing effect, replace the ember material annually. 

Replacement volcanic stone, glowing embers, and platinum 

embers are available.

       WARNING

 

DO NOT attempt to install the logs until the 

appliance installation has been completed, the 

gas line connected and tested for leaks and the 

initial burner operation has been checked out. 

 

The size and position of the log set was 

engineered to give the appliance a safe, reliable 

and attractive flame pattern. Any attempt to 

use a different log set in the fireplace will 

void the warranty and will result in incomplete 

combustion, sooting, and poor flame quality.

 

Logs get very hot and will remain hot up to one 

hour after gas supply is turned off. handle only 

when logs are cool. Turn off all electricity to 

the appliance before you install grate, volcanic 

stone, embers and logs.

 

This appliance is not designed to burn wood. Any 

attempt to do so could cause irreparable damage to 

the appliance and prove hazardous to your safety.

 

If logs are not installed according to the log 

installation instructions, flame impingement and 

improper combustion could occur and result in soot 

and/or excessive production of carbon monoxide 

(CO), a colorless, odorless, toxic gas.

Step 9. INSTALL VOLCANIC STONE, GLOWING EMBERS, AND 

LOGS (TRADITIONAL ONLY), OR  

GLASS MEDIA (CONTEMPORARY ONLY)

 Firebox Accessories

Cat. No.

Model

Description

88L53

FGE

Bag of Glowing Embers

80L42

FDVS

Bag of Volcanic Stone

H8312

PGE

Bag of Platinum Embers

Figure 32 - Volcanic Stone Placement 

Volcanic Stone

Figure 33 - Separating Glowing Embers

Figure 34 - Glowing Ember Placement

Glowing Embers (Rockwool)

Step 5.

 Position the individual logs as shown in Figures 36 through 39

Logs should be placed in the order shown. Place logs 2 and 3 

against the pins on the grate, NOT over them

.

 

Proper log and twig placement is critical to encourage outstand-

ing flame appearance and prevent sooting. When positioned 

properly, as shown, twigs will be positioned between flame 

peaks and will not impinge any flames.

       WARNING

 

DO NOT operate this appliance without the  

required accessories properly installed:

 - floor (log set or contemporary kit), and 

 - panels (ceramic or porcelain). 

Содержание DRC6345TYNDRC6340TYN

Страница 1: ...E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y TOUCHER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNC...

Страница 2: ...peration Page 21 Step 9 Installing Logs Page 22 Step 10 Install Remove Glass Door Assembly Page 24 Step11 Burner Adjustments Page 24 Finishing Requirements Page 26 Step 12 Attaching Safety in Operatio...

Страница 3: ...WER VENT DV GAS FIREPLACES DRT63__TYN DRC63__TYN INSTALLATION INSTRUCTIONS WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this...

Страница 4: ...let and OUT for the manifold side see Figure 1 Orifice Sizes Sea Level To High Altitude These appliances are tested and approved for installation at elevations of 0 4500 ft 0 1370 m above sea level us...

Страница 5: ...actured home in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition LOCATION In selecting the location the aesthetic and function...

Страница 6: ...ead combustible projection of 2 1 2 64 mm or less see Figure 3 For projections exceeding 2 1 2 64 mm see Figure 3 For additional vent location restrictions refer to Figure 4 on Page 7 INNOVATIVE HEART...

Страница 7: ...s 10 000 BTU hr 3kW and 100 000 BTU hr 30kW 36 91 cm for appliances 100 000 BTU hr 30kW 6 15 2 cm for appliances 10 000 BTU hr 3kW 9 23 cm for appliances 10 000 BTU hr 3kW and 50 000 BTU hr 15kW 12 30...

Страница 8: ...rated 175 F or higher on the underside of the mantel MINIMUM CLEARANCES TO COMBUSTIBLES Appliance And Vent Clearances The appliance is approved with zero clearance to combustible materials on all sid...

Страница 9: ...low for a minimum clearance to combustible framing members as shown in Table 5 on Page 8 If the appliance is to be elevated above floor level a solid continuous platform must be constructed below the...

Страница 10: ...el No A B C D E F G H J 40 in in 50 5 8 37 1 4 42 7 8 25 5 16 34 37 5 8 33 3 32 29 9 32 34 3 4 mm 1286 946 1089 643 864 956 840 744 883 45 in in 56 11 16 42 1 4 47 7 8 28 3 8 40 1 8 43 5 8 38 3 32 34...

Страница 11: ...8 59 1 8 41 7 8 mm 1286 2124 1502 1064 45 in in 56 3 4 89 7 8 63 1 2 44 7 8 mm 1441 2283 1613 1140 C Back wall of chase enclosure including any finishing materials D A B Figure 9 Corner Framing with...

Страница 12: ...Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or Canada CAN CGA B149 1 latest edition These fireplaces are designed tested and listed for operation and installation only with Secure Vent SV4 5 and...

Страница 13: ...1 0 8 4 0 4 1 1 0 0 0 1 1 1 2 9 4 1 4 1 0 1 0 0 1 2 1 5 9 9 4 5 2 6 1 4 0 0 0 1 0 1 1 1 4 0 5 2 4 1 0 0 1 0 1 2 1 5 1 1 5 5 2 6 2 4 0 0 0 0 1 1 1 1 5 0 2 5 5 7 3 3 4 0 2 0 1 1 1 4 1 1 3 5 5 2 4 4 0 2...

Страница 14: ...x 1 2 screw may be used at the joint butitisnotrequiredasthepipewillsecurely lock when twisted C Attachventcomponentstoeachother Other vent sections may be added to the previously installedsectioninac...

Страница 15: ...Secure Vent firestop spacer must be used anytime vent pipe passes through a combustible wall Maintain the horizontal inclined run in a straight slightly elevated plane approximately 1 4 per foot 20 mm...

Страница 16: ...vent sections in horizontal inclined run as described in Step E Install support straps every three feet 1914 mm along horizontal inclined vent runs using conventional plumber s tape see Figure 16 on P...

Страница 17: ...TE Centerline of Vent Piping is NOT the Same as the Centerline of the Frame Opening 6 to 48 Vent Section Telescopic vent section Elbow or Appliance Collar Base of Appliance 3 76 mm 1 25 4 mm Adaptor S...

Страница 18: ...fireplace to the newly installed junction box near the termination Ensure the cable is safety plated to prevent damage from framing nails and finish drywall screws Route it into the lower control com...

Страница 19: ...n it to fit within the junction box cover WARNING Crimp connectors may be used on stranded cables such as SJOT cable only Solid wire Romex must be connected per the National Electric Code NEC 70 lates...

Страница 20: ...t only be replaced as a complete unit as provided by the manufacturer Do not attempt to replace broken cracked or chipped glass separately INNOVATIVE HEARTH PRODUCTS POWER VENT DV GAS FIREPLACES DRT63...

Страница 21: ...ed above C When the gas lines are tested and leak free be sure to rinse off the leak testing solution D Re install the access plate making certain the gasket has not been damaged Figure 29 Fireplace R...

Страница 22: ...able and attractive flame pattern Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Logs get very h...

Страница 23: ...e And Push It Towards The Rear 3 2 4 1 6 5 7 Log Number Description 1 Log Center 2 Log Rear 3 Log Center Left 4 Log Center Right 5 Log Rear Top 6 Log Front Left 7 Log Front Center Table 6 Log Set Alig...

Страница 24: ...st be replaced prior to operating the appliance AVERTISSEMENT Tout cran ou pro tecteurretir pourpermettrel entretiende l appareil doit tre remis en place avant de mettre l appareil en marche Installin...

Страница 25: ...nstallation Leave the ON REMOTE OFF wall switch in the REMOTE position and turn the remote switch OFF Use the remote to adjust the flame height as desired CAUTION Soot will be produced if the air shut...

Страница 26: ...ed there are two methods of installation Combustible or noncombustible finish material may abut the front face of the fireplace and the floor panel see Figure 45 Combustible or noncombustible finish m...

Страница 27: ...ipalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour liminer la poussi re et les traces degraisseoud...

Страница 28: ...Section 77L72 SV4 5L24 24 610mm Vent Section 77L73 SV4 5L36 36 914mm Vent Section 77L74 SV4 5L48 48 1219mm Vent Section 77L75 SV4 5LA Telescopic Section 77L76 SV4 5E45 45 Degree Elbow 77L77 SV4 5E90 9...