background image

2

       WARNING 

Young children should be care-

fully supervised when they are 

in the same room as the appli-

ance. Toddlers, young children 

and others may be susceptible 

to accidental contact burns. A 

physical barrier is recommended 

if there are at risk individuals in 

the house. To restrict access to 

a fireplace or stove, install an 

adjustable safety gate to keep 

toddlers, young children and 

other at risk individuals out of 

the room and away from hot 

surfaces.

       AVERTISSEMENT 

Les jeunes enfants devraient être 

surveillés étroitement lorsqu’ils 

se trouvent dans la même pièce 

que l’appareil. Les tout petits, 

les jeunes enfants ou les adultes 

peuvent subir des brûlures s’ils 

viennent en contact avec la sur-

face chaude. Il est recommandé 

d’installer une barrière physique 

si des personnes à risques habi-

tent la maison. Pour empêcher 

l’accès à un foyer ou à un poêle, 

installez une barrière de sécu-

rité; cette mesure empêchera les 

tout petits, les jeunes enfants et 

toute autre personne à risque 

d’avoir accès à la pièce et aux 

surfaces chaudes.

GENERAL INFORMATION

INNOVATIVE HEARTH PRODUCTS  •  POWER VENT DV GAS FIREPLACES  (DRT63__TYN / DRC63__TYN)  •  INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS 

Packaging .........................................Page 2
Introduction ......................................Page 2

General Information

 ..........................Page 2

Massachusetts Requirements ...........Page 4
Cold Climate Insulation .....................Page 5
Manufactured Home Requirements ..Page 5

Location

 ............................................Page 5

Vent Termination Clearances  ............Page 6
Minimum Clearances to Combustibles Page 8
Pre-Installation Steps ........................Page 9
Typical Installation Sequence  ...........Page 9
Detailed Installation Steps .................Page 9

Step 1.  Framing

 ...............................Page 9

Fireplace and Framing Specifications

 Page 10 

Step 2.  Routing Gas Line

 ................Page 11

Proper Sizing of Gas Line

 ..................Page 11

Step 3.  Install the Vent System

 .......Page 12

General Vent Information

 ..................Page 12

Power Vent Components...................Page 12

Vent Section Length Chart

 ................

Page  13

Offset Installation ..............................

Page  13

Horizontal Termination System .........Page 16
Installing Power Vent Termination ....Page 16

Step 4.  Field Wiring

 .........................Page 18

Step 5.  Removing Glass Door Frame Assem

-

bly Page ....................................20

Step 6.  Connecting Gas Line

 ...........Page 21

Step 7  Install Firebox Liner

 ............Page 21

Step 8.  Verifying Appliance  
Operation ..........................................Page 21

Step 9.  Installing Logs 

 ...................Page 22

Step 10. Install/Remove Glass 

 

Door Assembly .................................Page 24
Step 11.  Burner Adjustments ............Page 24

Finishing Requirements

 ....................Page 26

Step 12. Attaching Safety-in- 
Operation Warnings ................... Page 27

Installation Accessories ....................Page 28

Please read and understand these instruc-
tions before beginning your installation.

PACKAGING

The assembled vented gas fireplace is packaged with:

BOX 1 - Fireplace:
  Literature Kit (plastic bag shipped inside 

firebox),

  Pull Screen

  Door Modesty Shield

  Adaptor with Probe Assembly

  (1) Remote Control Kit and Receiver Kit

BOX 2 - Power Vent Components:
  (1) Power Vent Termination
  (1) Termination Adaptor
  (1) Horizontal Firestop Assembly
  (1) Vacuum Hose
  (1) 11/32" Hose Clamp
  (1) Strain Relief
  (1) Bushing
  (4) Insulated 1/4" Male Terminals
  (2) #10 Ring Terminals

Traditional Fireplaces

•  Log set
•  Ceramic Firebox Liner Kit
•  One (1) bag Glowing Embers
•  One (1) bag Platinum Embers
•  One (1) bag Volcanic Stone
•  Log Grate 

Contemporary Fireplaces

•  Porcelain Firebox Liner Kit
•  One (1) bag Glass Media

INTRODUCTION 

These Electronic appliances are designed to 

operate on natural gas and have an electronic 

intermittent pilot ignition system. External 120 

Volt AC electrical power is required to operate 

these units.

These vented gas fireplaces are sealed combus

-

tion  gas  fireplaces  designed  for  residential, 

manufactured  home,  and  commercial  ap

-

plications.

Use Only These Approved Vent Components

 

These  fireplaces  are  designed,  tested  and 

listed for operation and installation with, the 

following (4-1/2" inner and 7-1/2" outer) vent 

components only:

•  Secure Vent

®

 Direct-vent system compo-

nents manufactured by Security Chimneys 

International.

These approved vent system components are 

labeled for identification. Do NOT use any other 

manufacturer’s vent components with these 

appliances.

Children and adults should be alerted to the haz-

ards of high surface temperature and should stay 

away to avoid burns or clothing ignition.

Les enfants et les adultes devraient être 

infor-més des dangers que posent les tem-

pératures de surface élevées et se tenir à 

distance afin d’éviter des brûlures ou que 

leurs vêtements ne s’enflamment.

DO NOT ATTEMPT TO ALTER OR MODIFY 

ThE CONSTRUCTION OF ThE APPLIANCE 

OR ITS COMPONENTS. ANY MODIFICATION 

OR ALTERATION MAY VOID ThE WARRANTY, 

CERTIFICATION AND LISTINGS OF ThIS UNIT.

Содержание DRC6345TYNDRC6340TYN

Страница 1: ...E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y TOUCHER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNC...

Страница 2: ...peration Page 21 Step 9 Installing Logs Page 22 Step 10 Install Remove Glass Door Assembly Page 24 Step11 Burner Adjustments Page 24 Finishing Requirements Page 26 Step 12 Attaching Safety in Operatio...

Страница 3: ...WER VENT DV GAS FIREPLACES DRT63__TYN DRC63__TYN INSTALLATION INSTRUCTIONS WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this...

Страница 4: ...let and OUT for the manifold side see Figure 1 Orifice Sizes Sea Level To High Altitude These appliances are tested and approved for installation at elevations of 0 4500 ft 0 1370 m above sea level us...

Страница 5: ...actured home in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition LOCATION In selecting the location the aesthetic and function...

Страница 6: ...ead combustible projection of 2 1 2 64 mm or less see Figure 3 For projections exceeding 2 1 2 64 mm see Figure 3 For additional vent location restrictions refer to Figure 4 on Page 7 INNOVATIVE HEART...

Страница 7: ...s 10 000 BTU hr 3kW and 100 000 BTU hr 30kW 36 91 cm for appliances 100 000 BTU hr 30kW 6 15 2 cm for appliances 10 000 BTU hr 3kW 9 23 cm for appliances 10 000 BTU hr 3kW and 50 000 BTU hr 15kW 12 30...

Страница 8: ...rated 175 F or higher on the underside of the mantel MINIMUM CLEARANCES TO COMBUSTIBLES Appliance And Vent Clearances The appliance is approved with zero clearance to combustible materials on all sid...

Страница 9: ...low for a minimum clearance to combustible framing members as shown in Table 5 on Page 8 If the appliance is to be elevated above floor level a solid continuous platform must be constructed below the...

Страница 10: ...el No A B C D E F G H J 40 in in 50 5 8 37 1 4 42 7 8 25 5 16 34 37 5 8 33 3 32 29 9 32 34 3 4 mm 1286 946 1089 643 864 956 840 744 883 45 in in 56 11 16 42 1 4 47 7 8 28 3 8 40 1 8 43 5 8 38 3 32 34...

Страница 11: ...8 59 1 8 41 7 8 mm 1286 2124 1502 1064 45 in in 56 3 4 89 7 8 63 1 2 44 7 8 mm 1441 2283 1613 1140 C Back wall of chase enclosure including any finishing materials D A B Figure 9 Corner Framing with...

Страница 12: ...Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or Canada CAN CGA B149 1 latest edition These fireplaces are designed tested and listed for operation and installation only with Secure Vent SV4 5 and...

Страница 13: ...1 0 8 4 0 4 1 1 0 0 0 1 1 1 2 9 4 1 4 1 0 1 0 0 1 2 1 5 9 9 4 5 2 6 1 4 0 0 0 1 0 1 1 1 4 0 5 2 4 1 0 0 1 0 1 2 1 5 1 1 5 5 2 6 2 4 0 0 0 0 1 1 1 1 5 0 2 5 5 7 3 3 4 0 2 0 1 1 1 4 1 1 3 5 5 2 4 4 0 2...

Страница 14: ...x 1 2 screw may be used at the joint butitisnotrequiredasthepipewillsecurely lock when twisted C Attachventcomponentstoeachother Other vent sections may be added to the previously installedsectioninac...

Страница 15: ...Secure Vent firestop spacer must be used anytime vent pipe passes through a combustible wall Maintain the horizontal inclined run in a straight slightly elevated plane approximately 1 4 per foot 20 mm...

Страница 16: ...vent sections in horizontal inclined run as described in Step E Install support straps every three feet 1914 mm along horizontal inclined vent runs using conventional plumber s tape see Figure 16 on P...

Страница 17: ...TE Centerline of Vent Piping is NOT the Same as the Centerline of the Frame Opening 6 to 48 Vent Section Telescopic vent section Elbow or Appliance Collar Base of Appliance 3 76 mm 1 25 4 mm Adaptor S...

Страница 18: ...fireplace to the newly installed junction box near the termination Ensure the cable is safety plated to prevent damage from framing nails and finish drywall screws Route it into the lower control com...

Страница 19: ...n it to fit within the junction box cover WARNING Crimp connectors may be used on stranded cables such as SJOT cable only Solid wire Romex must be connected per the National Electric Code NEC 70 lates...

Страница 20: ...t only be replaced as a complete unit as provided by the manufacturer Do not attempt to replace broken cracked or chipped glass separately INNOVATIVE HEARTH PRODUCTS POWER VENT DV GAS FIREPLACES DRT63...

Страница 21: ...ed above C When the gas lines are tested and leak free be sure to rinse off the leak testing solution D Re install the access plate making certain the gasket has not been damaged Figure 29 Fireplace R...

Страница 22: ...able and attractive flame pattern Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Logs get very h...

Страница 23: ...e And Push It Towards The Rear 3 2 4 1 6 5 7 Log Number Description 1 Log Center 2 Log Rear 3 Log Center Left 4 Log Center Right 5 Log Rear Top 6 Log Front Left 7 Log Front Center Table 6 Log Set Alig...

Страница 24: ...st be replaced prior to operating the appliance AVERTISSEMENT Tout cran ou pro tecteurretir pourpermettrel entretiende l appareil doit tre remis en place avant de mettre l appareil en marche Installin...

Страница 25: ...nstallation Leave the ON REMOTE OFF wall switch in the REMOTE position and turn the remote switch OFF Use the remote to adjust the flame height as desired CAUTION Soot will be produced if the air shut...

Страница 26: ...ed there are two methods of installation Combustible or noncombustible finish material may abut the front face of the fireplace and the floor panel see Figure 45 Combustible or noncombustible finish m...

Страница 27: ...ipalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour liminer la poussi re et les traces degraisseoud...

Страница 28: ...Section 77L72 SV4 5L24 24 610mm Vent Section 77L73 SV4 5L36 36 914mm Vent Section 77L74 SV4 5L48 48 1219mm Vent Section 77L75 SV4 5LA Telescopic Section 77L76 SV4 5E45 45 Degree Elbow 77L77 SV4 5E90 9...

Отзывы: