Step 4. FIELD WIRING
CAUTION: Label all wires prior to disconnection when servic-

ing controls. Wiring errors can cause improper and dangerous 

operation. 

ATTENTION: Au moment de l'entretien des commandes, 

étiquetez tous les fils avant de les débrancher. Des erreurs 

de cáblage peuvent entraîner un fonctionnement inadéquat 

et dangereux.

Verify proper operation after servicing.

S'assurer que l'appareil fonctionne adéquatement une fois 

l'entretien terminé.

CAUTION: Ground supply lead must be connected to the wire 

attached to the green ground screw located on the outlet box. 

See 

Figures 27 and 28 on Page 20

. Failure to do so will result 

in a potential safety hazard. The appliance must be electrically 

grounded in accordance with local codes or, in the absence of 

local codes, the (USA) National Electrical Code, ANSI/NFPA 

70 - latest edition, or the Canadian Electrical Code, CSA C22.1 

- latest edition.
Route Cable

NOTE: Electrical wiring must be performed by a qualified electrician.

•  Install the strain relief in the hole provided on the right side of fireplace 

for the electrical wiring (see

 Figure 20).

•  Either use the intgrated junction box, or position an electrical junction 

box (not provided) within reach of the termination wiring pigtail (see

 

Figure 23 on Page 19)

. Route the pigtail to the junction box as the 

termination is installed.

•  Route 14 gage AWG grounded solid wire Romex

®

 or equally-sized 

stranded cable (e.g., SJOT) from the fireplace to the newly installed 

junction box near the termination. Ensure the cable is safety plated to 

prevent damage from framing nails and finish drywall screws. Route 

it into the lower control compartment and cut to length before install-

ing the terminals. Install provided hardware on the ends of the cable. 

Cable is not provided. The provided crimp terminals are intended for 

use with stranded cable. If using Romex, connect per National Electric 

Code or local code. 

14 Gage 

Grounded 

Romex or 

similar 

Stranded 

Cable

Strain 

Relief 

Vacuum 

hose

Snap 

Bushing

Wall Switch

harness

Junction Box

Right Side 

of Fireplace

Probe (1 *)

hose Clamp (7 *)

Vacuum hose (2 *)

* See Figure 11 on Page 12

Adaptor Assembly

Pressure Switch

Pressure Switch

Vacuum hose

Firebox

Pressure switch is located 

behind the panel on the right 

side of firebox

Vacuum hose

•  Refer to 

Figure 25 on Page 19 and install the electrical hardware on 

the ends of the cable. Male terminals on the Black and White wires, 

and ring terminals on the ground wire.

•  Using standard electrical practices and the terminals provided, con

-

nect the three wires of the cable to the termination pigtail within the 

Electrical junction box. Ensure ground.

•  The fireplace end of the cable will be addressed in Connecting The 

Power Vent To The Fireplace Control System

.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 20 - Routing Wiring

Figure 21 - Vacuum Hose Connection to Probe 

Figure 22 - Vacuum Hose Connection to Pressure Switch 

NOTE: Pressure switch style may vary from that shown.

INNOVATIVE HEARTH PRODUCTS  •  POWER VENT DV GAS FIREPLACES  (DRT63__TYN / DRC63__TYN)  •  INSTALLATION INSTRUCTIONS

Содержание DRC6345TYNDRC6340TYN

Страница 1: ...E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y TOUCHER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNC...

Страница 2: ...peration Page 21 Step 9 Installing Logs Page 22 Step 10 Install Remove Glass Door Assembly Page 24 Step11 Burner Adjustments Page 24 Finishing Requirements Page 26 Step 12 Attaching Safety in Operatio...

Страница 3: ...WER VENT DV GAS FIREPLACES DRT63__TYN DRC63__TYN INSTALLATION INSTRUCTIONS WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this...

Страница 4: ...let and OUT for the manifold side see Figure 1 Orifice Sizes Sea Level To High Altitude These appliances are tested and approved for installation at elevations of 0 4500 ft 0 1370 m above sea level us...

Страница 5: ...actured home in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition LOCATION In selecting the location the aesthetic and function...

Страница 6: ...ead combustible projection of 2 1 2 64 mm or less see Figure 3 For projections exceeding 2 1 2 64 mm see Figure 3 For additional vent location restrictions refer to Figure 4 on Page 7 INNOVATIVE HEART...

Страница 7: ...s 10 000 BTU hr 3kW and 100 000 BTU hr 30kW 36 91 cm for appliances 100 000 BTU hr 30kW 6 15 2 cm for appliances 10 000 BTU hr 3kW 9 23 cm for appliances 10 000 BTU hr 3kW and 50 000 BTU hr 15kW 12 30...

Страница 8: ...rated 175 F or higher on the underside of the mantel MINIMUM CLEARANCES TO COMBUSTIBLES Appliance And Vent Clearances The appliance is approved with zero clearance to combustible materials on all sid...

Страница 9: ...low for a minimum clearance to combustible framing members as shown in Table 5 on Page 8 If the appliance is to be elevated above floor level a solid continuous platform must be constructed below the...

Страница 10: ...el No A B C D E F G H J 40 in in 50 5 8 37 1 4 42 7 8 25 5 16 34 37 5 8 33 3 32 29 9 32 34 3 4 mm 1286 946 1089 643 864 956 840 744 883 45 in in 56 11 16 42 1 4 47 7 8 28 3 8 40 1 8 43 5 8 38 3 32 34...

Страница 11: ...8 59 1 8 41 7 8 mm 1286 2124 1502 1064 45 in in 56 3 4 89 7 8 63 1 2 44 7 8 mm 1441 2283 1613 1140 C Back wall of chase enclosure including any finishing materials D A B Figure 9 Corner Framing with...

Страница 12: ...Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or Canada CAN CGA B149 1 latest edition These fireplaces are designed tested and listed for operation and installation only with Secure Vent SV4 5 and...

Страница 13: ...1 0 8 4 0 4 1 1 0 0 0 1 1 1 2 9 4 1 4 1 0 1 0 0 1 2 1 5 9 9 4 5 2 6 1 4 0 0 0 1 0 1 1 1 4 0 5 2 4 1 0 0 1 0 1 2 1 5 1 1 5 5 2 6 2 4 0 0 0 0 1 1 1 1 5 0 2 5 5 7 3 3 4 0 2 0 1 1 1 4 1 1 3 5 5 2 4 4 0 2...

Страница 14: ...x 1 2 screw may be used at the joint butitisnotrequiredasthepipewillsecurely lock when twisted C Attachventcomponentstoeachother Other vent sections may be added to the previously installedsectioninac...

Страница 15: ...Secure Vent firestop spacer must be used anytime vent pipe passes through a combustible wall Maintain the horizontal inclined run in a straight slightly elevated plane approximately 1 4 per foot 20 mm...

Страница 16: ...vent sections in horizontal inclined run as described in Step E Install support straps every three feet 1914 mm along horizontal inclined vent runs using conventional plumber s tape see Figure 16 on P...

Страница 17: ...TE Centerline of Vent Piping is NOT the Same as the Centerline of the Frame Opening 6 to 48 Vent Section Telescopic vent section Elbow or Appliance Collar Base of Appliance 3 76 mm 1 25 4 mm Adaptor S...

Страница 18: ...fireplace to the newly installed junction box near the termination Ensure the cable is safety plated to prevent damage from framing nails and finish drywall screws Route it into the lower control com...

Страница 19: ...n it to fit within the junction box cover WARNING Crimp connectors may be used on stranded cables such as SJOT cable only Solid wire Romex must be connected per the National Electric Code NEC 70 lates...

Страница 20: ...t only be replaced as a complete unit as provided by the manufacturer Do not attempt to replace broken cracked or chipped glass separately INNOVATIVE HEARTH PRODUCTS POWER VENT DV GAS FIREPLACES DRT63...

Страница 21: ...ed above C When the gas lines are tested and leak free be sure to rinse off the leak testing solution D Re install the access plate making certain the gasket has not been damaged Figure 29 Fireplace R...

Страница 22: ...able and attractive flame pattern Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Logs get very h...

Страница 23: ...e And Push It Towards The Rear 3 2 4 1 6 5 7 Log Number Description 1 Log Center 2 Log Rear 3 Log Center Left 4 Log Center Right 5 Log Rear Top 6 Log Front Left 7 Log Front Center Table 6 Log Set Alig...

Страница 24: ...st be replaced prior to operating the appliance AVERTISSEMENT Tout cran ou pro tecteurretir pourpermettrel entretiende l appareil doit tre remis en place avant de mettre l appareil en marche Installin...

Страница 25: ...nstallation Leave the ON REMOTE OFF wall switch in the REMOTE position and turn the remote switch OFF Use the remote to adjust the flame height as desired CAUTION Soot will be produced if the air shut...

Страница 26: ...ed there are two methods of installation Combustible or noncombustible finish material may abut the front face of the fireplace and the floor panel see Figure 45 Combustible or noncombustible finish m...

Страница 27: ...ipalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour liminer la poussi re et les traces degraisseoud...

Страница 28: ...Section 77L72 SV4 5L24 24 610mm Vent Section 77L73 SV4 5L36 36 914mm Vent Section 77L74 SV4 5L48 48 1219mm Vent Section 77L75 SV4 5LA Telescopic Section 77L76 SV4 5E45 45 Degree Elbow 77L77 SV4 5E90 9...

Отзывы: