10
Function No. : 010
1
st
Needle Speed Setting
Function No. : 011
2
nd
Needle Speed Setting
Function No. : 012
3
rd
Needle Speed Setting
User sets the speed for the 3
rd
needle.
User sets the speed for the 3
rd
needle (default value: 4[100ms])
[ Contents ] This function is used when the set value of Parameter “009. Slow Start
Main Shaft Acceleration" is “7) User Define."
012. User_Slow_3
2~25[100ms]
Setting
Value
User sets the speed for the 2
nd
needle.
User sets the speed for the 2
nd
needle (default value: 2[100ms])
[ Contents ] This function is used when the set value of Parameter “009. Slow Start
Main Shaft Acceleration" is “7) User Define."
011. User_Slow_2
2~25[100ms]
Setting
Value
User sets the speed for the 1
st
needle.
User sets the speed for the 1
st
needle (default value: 2[100ms])
[ Contents ] This function is used when the set value of Parameter “009. Slow Start
Main Shaft Acceleration" is “7) User Define."
010. User_Slow_1
2~25[100ms]
Setting
Value
Function No. : 013
4
th
Needle Speed Setting
User sets the speed for the 4
th
needle.
User sets the speed for the 4
th
needle (default value: 6[100ms])
[ Contents ] This function is used when the set value of Parameter “009. Slow Start
Main Shaft Acceleration" is “) User Define."
013. User_Slow_4
2~25[100ms]
Setting
Value