49
Function No. : 103
Function Name : Extended I/O board setting
When the extended I/O board is used, signal input/output function can be set.
Not used (default value)
[Contents] Machine operation is same as before when the function is disabled.
103. EX_IO BD SET
1) DISABLE
Setting
Value
Use the input/output signals
[Contents] Sewing can start with input signal or output signal can be sent out during
sewing.
2) ENABLE
Function No. : 104
Function Name : Design Preview Setting
Press the number keys to check the saved designs and set the call method
(limited to Graphic OP)
.
Not used
[Contents] Machine operation is same as before when the function is disabled.
104. Thumbnail Set
1) DISABLE
Setting
Value
Give a preview of saved designs in the thumbnail form. (default value)
[Contents] Press the number keys to select a storage device among Memory, USB flash
drive. Check and call the saved designs.
2) ENABLE
Function No. : 105
Function Name : Upper/Lower Shaft Origin Search Motion Setting
Set the upper/lower shaft origin search motion after sewing completion.
Not used
[Contents] The upper/lower shaft origin search motion does not take place.
105. Hook ORG Mode
1) JOB_SETUP
Origin search takes place after trimming.
[Contents] After trimming, the upper/lower shaft origin search takes place.
3) JOB_TRIM
Setting
Value
Used (default value)
[Contents] The upper/lower shaft origin search motion takes place when sewing is
completed. Unlike the existing pattern machines, the upper and lower shafts are
separated and operating independently. Therefore, when the motion is finished,
their origin search should be made for accurate setting of upper/lower shaft
hook timing.
2) JOB_READY
[Note] Do not enable the function before making a link to the extended board.
If the function is enabled without connection, the standby mode may be set and no motion will take
place. In this case, the connection to the extended board enables the return to the normal status.
Note