53
Function No. : 115
Function Name : Setting the head sensor
The sensor at the left side of the head recognizes the right position of the sensor. If the head is not
properly positioned, sewing doesn’t start.
Not used
[Contents] When the head sensor operation is not selected, sewing can start although the head is
not properly positioned.
115. Head Sensor
1) DISABLE
Setting
Value
Used
[Contents] Sewing starts only after it is made sure that the head sensor is properly positioned.
2) ENABLE
Function No. : 116
Function Name : Clamp Sensor Setting
The left and right sensors check the proper attachment of the clamp. If more than one sensor fails
to detect the clamp, the machine does not operate. This function applies when the removable
clamp is used. [Cassette zig model.]
The clamp sensor is not used.
[Contents] Even though the sensor does not detect the clamp, forcible sewing is possible.
116. Clamp Sensor
1) DISABLE
Setting
Value
The clamp sensor is used.
When the function is tried to use without the attachment of the cassette zig, the sewing is not started.
[Contents] If either one of the left and right sensors fail to detect the clamp, sewing is not
conducted.
2) ENABLE
Function No. : 117
Function Name : Barcode origin point selection
Up to four barcode origin points can be set.
[Contents] Set the barcode origin point 1.
117. BCODE ORG SET
1) B_ORG_PNT_1
Setting
Value
[Contents] Set the barcode origin point 2.
2) B_ORG_PNT_2
[Contents] Set the barcode origin point 3.
3) B_ORG_PNT_3
[Contents] Set the barcode origin point 4.
4) B_ORG_PNT_4