185
※
Connect the RA2611 connector of the auto call function cable to CN22 on the I/O board.
▶
See the 'Description on connector and jumper pin locations' below regarding the connector locations on the
I/O board.
▶
See the cable specifications for cable connectors.
※
A total of 8 adjacent cables are used. Please request the desired number of adjacent sensor cables.
Cable name
Product No.
Cable connecting position
(SPS/B, A-Series) Auto call function cable
Adjacent sensor cable
CA-003043,00Ä
CA-002857,00
CN22 on the I/O board
SMR-03V-N of the auto call function cable
③
Cables connected by user
④
Cable signal input information
1
+5V or +24V
BR1
SEN_0
2
SEN_0
3
GND
1
+5V or +24V
BR2
SEN_1
2
SEN_1
3
GND
1
+5V or +24V
BR3
SEN_2
2
SEN_2
3
GND
1
+5V or +24V
BR4
SEN_3
2
SEN_3
3
GND
1
+5V or +24V
BR5
CLAMP
2
Clamp driving signal
3
GND
1
+5V or +24V
BR6
EM-STOP
2
Emergency stop signal
3
GND
1
+5V or +24V
BR7
START
2
Signal line for sewing start signal
3
GND
1
+5V or +24V
BR8
ENTER
2
Signal line for ready signal
3
GND
Signal name
Connector pin number
(SMR-03V-N)
Description
Jumper pin for voltage
change