144
Function No. : 063
Function Name : Setting the magnifying/demagnifying mode
It is to select and set the magnifying/demagnifying mode.
The Magnifying/demagnifying function is not used.
[Contents] The machine uses the pattern data in the programmed size.
As the magnifying/demagnifying function is not selected, the X scale , Y scale
keys are not operated. Adjust the "XS" and "YS" indicated on the screen to 100%
063. Scale Mode
1) DISABLE
Setting
Value
It is to set the magnifying/demagnifying mode using the stitch length.
(Factory installed condition)
[Contents] While the number of stitches are the same, the length of the stitches along
the X and Y axis are adjusted according to the magnifying/demagnifying rate.
Set the rate within the feed plate transfer limit.
2) STITCH_LEN
It is to set the magnifying/demagnifying mode using the number of stitches.
[Contents] While the length of stitches are the same, the number of stitches are adjusted
along the X and Y axis. Set the rate within the feed plate transfer limit.
3) STITCH_NUM
It is not applied
(It is going to apply
later)
Magnifying/demagnifying
according to stitch length
Magnifying/demagnifying
according to number of stitches
Содержание SPS/A-Pattern Series
Страница 174: ...174 5 SPS A B C Series block diagram SPS B 1306 BLOCK DIAGRAM ...
Страница 175: ... Input Voltage Type POWER DIAGRAM 1306 175 ...
Страница 176: ... SPS A 1306 Series BLOCK DIAGRAM 176 ...
Страница 177: ...177 SPS C Series BLOCK DIAGRAM ...
Страница 178: ...6 Table Drawing 178 ...