152
Function No. : 078
Function Name : Sewing limit set-up
Designed to ensure the user to increase the mechanical sewing limit of the machine as desired
SPS/C-Series can not be used.
Not in use (When shipped out from the factory)
[Contents] The sewing limit cannot be expanded. Use the sewing limit as defined by type.
078. Sewing Limit
1) DISABLE
Setting
Value
In use
[Contents] The user can expand the sewing limit.
[Caution] On condition that sewing limit is changed in accordance with mechanically expanded limit.
Otherwise, the machine can be damaged.
2) ENABLE
Function No. : 079
Function Name : X-axis forward direction sewing limit set-up
The user can increase the X-axis forward direction as desired.
Set the size of X-axis forward direction as desired. (At the time of the factory shipping,
machines are set in line with their sewing limit by type)
Ex: 13mm for 1306 type
079. XPLUS Limit
1~250mm
Setting
Value
[Contents] The user can expand the size of sewing limit in the program.
[Caution] The feeding axis must be changed in line with the size of sewing limit where
mechanical feeding is possible. If the user increases the set-up value in the program
and begins feeding, the machine can be severely damaged.
Function No. : 080
Function Name : X-axis reverse direction sewing limit set-up
The user can increase the X-axis reverse direction of the sewing limit
Set the size of X-axis reverse direction as desired. (At the time of the factory shipping,
machines are set in line with their sewing limit by type)
Ex: -13mm for 1306 type
080. XMINUS Limit
-1~-250mm
Setting
Value
[Contents] The user can expand the size of sewing limit in the program.
[Caution] The feeding axis must be changed in line with the size of sewing limit where
mechanical feeding is possible. If the user increases the set-up value in the program
and begins feeding, the machine can be severely damaged.
Содержание SPS/A-Pattern Series
Страница 174: ...174 5 SPS A B C Series block diagram SPS B 1306 BLOCK DIAGRAM ...
Страница 175: ... Input Voltage Type POWER DIAGRAM 1306 175 ...
Страница 176: ... SPS A 1306 Series BLOCK DIAGRAM 176 ...
Страница 177: ...177 SPS C Series BLOCK DIAGRAM ...
Страница 178: ...6 Table Drawing 178 ...