18
F. The following shows an example of situations
where the safety mode is activated. Thread is
broken in the middle of sewing.
When the thread is sensed, an alarm is issued
and the OP Box displays the following
message. While the message is displayed on
the OP Box screen, Pedal Start Switch,
Clamp Up/Down Switch, and Keys of the OP
Box remain disabled in order to protect users.
Only when the exit key is entered, the
functions mentioned above are operable. To
cancel the safety mode, press “EXE” on the
left bottom of the OP Box. When this key is
pressed, the sewing machine operation will go
back to normal.
While the safety mode is effective, the clamp
is located down.
G. To cancel this function, press EXE Key on
the OP Box. This is the message you can
see on the OP Box screen.
After the function is cancelled, the sewing
machine can be operated again.
E r r 1 8
T h r e a d B r o k e n !
P r e s s E X E K e y
S e w i n g i s r e a d y
O K !
H. Sewing can be started by pressing the Pedal
Start Switch.
N O : 0 0 3 N O R _ S E W
X S : 1 0 0 %
Y S : 1 0 0 % S P : 2 0 0 0
B C : 1 0 0 P C : 0 0 0 0
N O : 1 2 3 N O R _ S E W
X S : 1 0 0 %
Y S : 1 0 0 % S P : 1 5 0 0
B C : 0 0 4 P C : 9 0 8 4
Содержание SPS/A-Pattern Series
Страница 174: ...174 5 SPS A B C Series block diagram SPS B 1306 BLOCK DIAGRAM ...
Страница 175: ... Input Voltage Type POWER DIAGRAM 1306 175 ...
Страница 176: ... SPS A 1306 Series BLOCK DIAGRAM 176 ...
Страница 177: ...177 SPS C Series BLOCK DIAGRAM ...
Страница 178: ...6 Table Drawing 178 ...