160
Function No. : 102
Function Name: Program mode lock
This function locks the program mode of the main menu.
Disabled (Default)
[Contents] When the function is disabled, the usage of program mode is as same as before.
In use
[Contents] When the function is enabled, it is impossible to enter the program mode.
102. Program Lock
1) DISABLE
2) ENABLE
Setting
Value
Function No. : 103
Function Name: Semi-auto removal of lower feed plate(SPS-3020, 5030, 5034)
When sewing is completed, the lower feed plate is automatically removed.
Disabled (Default)
[Contents] When the function is disabled, the usage of program mode is as same as before.
In use
[Contents] When the function is enabled, the lower feed plate is automatically removed.
103. Low Feed Set
1) DISABLE
2) ENABLE
Setting
Value
Function No. : 104
Function Name: Basic clamp position setting
This function sets the basic position of the clamp.
Disabled (Default)
[Contents] When the function is disabled, the usage of program mode is as same as before.
In use
[Contents] For use, the clamp
’
s pneumatic lines A and B shall be exchanged before connection.
104. Clmp Ref POS
1) Ref_UP
2) Ref_DOWN
Setting
Value