User Manual
11 Appendix
87
Parameters
SG60KTL
Protection
Islanding protection
Yes
LVRT Yes
AC short circuit
protection
Yes
Leakage current
protection
Yes
DC switch
Integrated
Overvoltage protection
DC Type II; AC Type
Ⅲ
System data
Max. efficiency
98.9%
Max. European
efficiency
98.7%
Isolation method
Transformerless
Ingress protection
rating
IP65
Night power
consumption
<1W
Operating ambient
temperature range
-25~
+
60
℃
(>50
℃
derating)
Allowable relative
humidity range
0~100%
Cooling concept
Smart forced air cooling
Max. operating altitude
4000m (>3000m derating)
Display Graphic
LCD
Communication RS485
DC terminal
Screw-crimp terminal
AC terminal
Screw-crimp terminal
Certification
VDE0126-1-1,EN62109-1,EN62109-2,G59/3,CEI-021,AS/NZS
3100,AS4777.2,AS4777.3,VDE-AR-N-4105,BDEW, CGC
Mechanical Data
Dimensions (W
×
H
×
D) 634
×
959
×
267mm
Mounting method
Wall bracket
Weight 60kg
11.2 Exclusion of Liability
The content of these documents is periodically checked and revised where
necessary. Please call us or check our website
www.sungrowpower.com
for the
latest information. No guarantee is made for the completeness of these documents.
Please contact our company or distributors for the latest version.
Guarantee or liability claims for damages of any kind are excluded if they are caused
Improper or inappropriate use or install of the product
Содержание SG60KTL
Страница 1: ...SG60KTL V142 UEN Ver11 201712 Version 1 1 User Manual SG60KTL PV Grid connected Inverter ...
Страница 2: ......
Страница 5: ...III Symbols on the Inverter Body ...
Страница 10: ......
Страница 23: ...User Manual 2 Product Description 13 P Vmin 266V Pn Vgrid 230V Fig 2 6 Grid under voltage derating ...
Страница 71: ...User Manual 10 Operation of LCD Display 61 10 2 Menu Tree Fig 10 1 Menu tree ...