Duct description
Round duct
Rectangle duct
Dimension (mm)
Ф
160
160×160
Straight-line pressure drop (Pa/m)
≤
2
≤
2
Straight-line length (m)
≤
5
≤
5
Bent pressure drop (Pa)
≤
2
≤
2
Bent’s quantity
≤
5
≤
5
The duct’s resistance will decrease air-flow-rate, and capacity of unit will be decreased.
It is recommended to install the unit in the indoor space. It is not allow installing the unit at
the rainy space.
In terms of the unit connect with duct reaching to outdoor, and then a reliable water-resistant
measure must be conduct on the duct, to prevent water from dropping into internal of the unit.
Filter should be installed at the unit inlet, if the air inlet is not connected with duct. In terms of
the unit with duct, filter should be put on the position of duct inlet.
ATTENTION!
Do not dismantle the PT Valve or block off the Drainage pipe, It will cause
explosion and injury