16
Electric connection
If the power supply is not earthed well, the unit should be not installed.
The reliable earthing connection and the installation of the unit should be done by a
qualified person.
The power supply should be an independent circuit with rated voltage.
An all-pole disconnection device which has at least 3mm separation distance in all pole and
a residual current device (RCD) with the rating of above 10mA shall be incorporated in the
fixed wiring according to the national rule.
Set the electric leakage protector according to the relevant electric technical standards of
the local.
The power cord and the signal cord shall be laid out neatly and properly without mutual
interference or contacting the connection pipe or valve.
After wire connection, check it again and make sure the correctness before power on.
Specifications of power supply
Model name
Calor Top 200D
Power supply
220-240V~, 50Hz, 1Ph
Min. diameter of power supply cord (mm
2
)
4
Earth cord (mm
2
)
4
Manual switch capacity (A)/Fuse (A)
25/20
Creepage breaker
30Ma,
≤
0.1sec
Choosing the power cord according to above table, and it should comply with local electric
standard.
The power cord model, recommended power cord mode is H05RN-F.