
Chapter 3
Maintaining the Sun Fire X4500 and X4540 Servers
3-65
Note –
For optimum performance, all DIMMs controlled by a given CPU should be
the same capacity and all single-rank or dual-rank. Mixed configurations are
supported, but could result in lower memory performance. Note that all supported
4GB and 8GB DIMMs are dual-rank. For 1GB and 2GB DIMMs, you can identify the
type by counting the DRAMs; single-rank DIMMs have 18 DRAMs, while dual-rank
DIMMs have 36 DRAMs.
1. Read Steps 1 through 5 in
“To Remove Memory Modules (DIMMs) (CRU)” on
page 3-61
.
2. Install the DIMMs.
a. Ensure that the DIMM slot ejectors at each end of the memory socket are
fully open (rotated outward) to accept the new DIMM.
b. Align the notch in the bottom edge of the DIMM with the key in the DIMM
socket. See
FIGURE 3-29
.
c. Press down evenly on both top corners of the DIMM until the ejectors snap
over the cutouts in the left and right edges of the DIMM.
3. Replace the system controller to the server (X4500).
See
“Replacing the System Controller (FRU)” on page 3-68
.
4. Replace the cable management assembly if necessary. See one of the following
docs depending on your CMA version:
■
Sun Fire X4500/X4540 Installation Guide
■
Sun X4500-J Slide Rail Installation Guide
(X4500)
■
“Early-Production Slide Rail and CMA Information” on page G-1
(X4500)
▼
To Install a PCI-X or PCIe Card (FRU)
The Sun Fire X4500 accommodates up to two PCI-X cards and the X4540 servers
accommodates up to three PCIe expansion cards that meet PCI 2.2 specifications and
the PCI-X Mechanical and Electrical Addendum with the following limitations:
■
Low-profile cards only
■
MD2 (6.600-in. reference) maximum length cards
■
Standard component height limits
■
25W maximum power per card
Содержание 4540 - Phaser Copystation
Страница 1: ...Sun Fire X4500 X4540 Server Service Manual Service Manual Part No 819 4359 19 May 2010 Revision A...
Страница 12: ...xii Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 34: ...1 20 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 192: ...3 72 Sun Fire X4500 X4540 Server Service Manual May 2010 FIGURE 3 31 Removing the System Controller...
Страница 196: ...3 76 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 210: ...B 12 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 217: ...Appendix C Status Indicator LEDs C 7 FIGURE C 3 Disk Drive and Fan Trays X4500 Figure Legend 0 Boot drive 1 Boot drive...
Страница 219: ...Appendix C Status Indicator LEDs C 9 FIGURE C 5 Disk Drive and Fan Tray LEDs...
Страница 250: ...E 6 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 256: ...G 4 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 264: ...Index 4 Sun Fire X4500 X4540 Server Service Manual May 2010...