3-64
Sun Fire X4500/X4540 Server Service Manual • May 2010
6. To remove a DIMM:
a. Rotate both DIMM slot ejectors outward as far as they will go. The DIMM is
partially ejected from the socket. See
FIGURE 3-29
.
b. Carefully lift the DIMM straight up to remove it from the socket.
▼
To Install Memory Modules (DIMMs) (CRU)
TABLE 3-18
lists the qualified part numbers for this component. These part numbers
are subject to change over time. For an updated list of components, see the following
web site:
http://sunsolve.sun.com/handbook_pub/Systems/
Note –
If you are installing DIMMs for the first time, the DIMMs must be populated
in matching pairs. The first DIMMs installed must be installed in the slots furthest
from the CPU. Then, the next two closest slots are populated, and so on. There are
four DIMM slots for the X4500 and eight DIMM slots for the X4540.
TABLE 3-18
Sun Fire X4500/X4540 Supported DIMM Part Numbers
Component
Part Number
4GB DDR1-400 memory (2x2GB) (X4500)
#371-1964,
X4231A-Z (X-option)
4GB DDR2-667 memory (2x2GB), 512Mb based (X4540)
#541-1313,
X5034 (X-option)
4GB DDR2-667 memory (2x2GB), 1GB based (X4540)
#541-3360,
X4540 (X-option)
8GB DDR2-667 memory (2x4GB), 1GB based (X4540)
#541-1304,
X5035 (X-option)
8GB DDR2-667 memory (2x8GB), 2GB based (X4540)
#541-3419,
X8356A (X-option)
Содержание 4540 - Phaser Copystation
Страница 1: ...Sun Fire X4500 X4540 Server Service Manual Service Manual Part No 819 4359 19 May 2010 Revision A...
Страница 12: ...xii Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 34: ...1 20 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 192: ...3 72 Sun Fire X4500 X4540 Server Service Manual May 2010 FIGURE 3 31 Removing the System Controller...
Страница 196: ...3 76 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 210: ...B 12 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 217: ...Appendix C Status Indicator LEDs C 7 FIGURE C 3 Disk Drive and Fan Trays X4500 Figure Legend 0 Boot drive 1 Boot drive...
Страница 219: ...Appendix C Status Indicator LEDs C 9 FIGURE C 5 Disk Drive and Fan Tray LEDs...
Страница 250: ...E 6 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 256: ...G 4 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 264: ...Index 4 Sun Fire X4500 X4540 Server Service Manual May 2010...