
3-6
Sun Fire X4500/X4540 Server Service Manual • May 2010
■
X311 or local equivalent (Power Cord Kit, North American/Asian)
Note –
The third power supply is not supported in an older X4540 (#541-1218) or the
Sun Fire X4500 system.
Note –
When a system is configured for 3 PSUs at 100-120V AC and only 2 PSUs are
installed, the amber System Fault LED LED illuminates.
For power supply part numbers, see
“Replacing a Power Supply (CRU)” on
page 3-40
.
3.4
System Model Numbers (X4540)
The following 2356 CPUs are supported by the X4540:
TABLE 3-3
Enhanced Quad-Core AMD Opteron Processor, Model 2356
Part
Number
Description
Model Numbers
#371-4042
2 Quad-core AMD Opteron 2356 CPUs (2.3 GHz, 75W ACP),
2x2356, 16x2GB DDR2-667, 48x250GB
B24-FSZ2-32F-GMH
2 Quad-core AMD Opteron 2356 CPUs (2.3 GHz, 75W ACP),
2x2356, 16x2GB DDR2-667, 48x500GB
B24-FSZ2-32F-HMH
2 Quad-core AMD Opteron 2356 CPUs (2.3 GHz, 75W ACP),
2x2356, 16x2GB DDR2-667, 48x1TB
B24-FSZ2-32F-SMH
2 Quad-core AMD Opteron 2356 CPUs (2.3 GHz, 75W ACP),
2x2356, 16x4GB DDR2-667, 48x500
B24-FSZ2-64G-HMH
2 Quad-core AMD Opteron 2356 CPUs (2.3 GHz, 75W ACP),
2x2356, 16x4GB DDR2-667, 48x1TB
B24-FSZ2-64G-SMH
2 Quad-core AMD Opteron 2356 CPUs (2.3 GHz, 75W ACP),
2x2356, 16x2GB (1Gb), 48x250GB
B24-FSZ2-32F-GMH
2 Quad-core AMD Opteron 2356 CPUs (2.3 GHz, 75W ACP),
2x2356, 16x2GB (1Gb), 48x500GB
B24-FSZ2-32F-HMH
2 Quad-core AMD Opteron 2356 CPUs (2.3 GHz, 75W ACP),
2x2356, 16x2GB (1Gb), 48x1TB
B24-FSZ2-32F-SMH
Содержание 4540 - Phaser Copystation
Страница 1: ...Sun Fire X4500 X4540 Server Service Manual Service Manual Part No 819 4359 19 May 2010 Revision A...
Страница 12: ...xii Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 34: ...1 20 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 192: ...3 72 Sun Fire X4500 X4540 Server Service Manual May 2010 FIGURE 3 31 Removing the System Controller...
Страница 196: ...3 76 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 210: ...B 12 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 217: ...Appendix C Status Indicator LEDs C 7 FIGURE C 3 Disk Drive and Fan Trays X4500 Figure Legend 0 Boot drive 1 Boot drive...
Страница 219: ...Appendix C Status Indicator LEDs C 9 FIGURE C 5 Disk Drive and Fan Tray LEDs...
Страница 250: ...E 6 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 256: ...G 4 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 264: ...Index 4 Sun Fire X4500 X4540 Server Service Manual May 2010...