Chapter 3
Maintaining the Sun Fire X4500 and X4540 Servers
3-31
11. Replace the disk drives access cover and, using a No. 1 Phillips screwdriver,
tighten the two screws on the left and right sides. See
Section t, “To Remove the
Drives Access Cover” on page 3-13
.
▼
To Replace a Hard Drive (CRU)
This section describes how to remove and replace a drive. It is a good practice to
allocate five drives (roughly 10 percent of the total capacity) as hot spares.
Note –
This component is a hot-pluggable CRU and can be replaced by anyone.
Hot-pluggable means that the disk drive must be first brought offline by using a
management software or operating system command; however, the server does not
need to be powered off.
The system designation of the drives is shown on the service label.
TABLE 3-10
lists the qualified part numbers for this component. These part numbers
are subject to change over time.
Note –
Do not mix drives of different drive capacities.
For an updated list of components, see the following web site:
http://sunsolve.sun.com/handbook_pub/Systems/
TABLE 3-10
Hard Drives for the X4500 Server
Disk Drive
Part Number
Seagate 250GB SATA 3.5” drive (X4500)
#541-1468,
XRA-ST1CH-250G7KZ (X-option)
Hitachi 500GB, SATA, 3.5” drive (X4500, X4540)
#541-3050,
XRA-ST1CH-500G7KZ (X-option)
Hitachi 750GB, SATA, 3.5” drive (X4500, migrated
X4540*)
#540-7244,
XRA-ST1CH-750G7KZ (X-option)
Hitachi 1-TB , SATA 3.5" drive (X4500, X4540)
#540-7507,
XRA-ST1CH-1T7K (X-option)
Содержание 4540 - Phaser Copystation
Страница 1: ...Sun Fire X4500 X4540 Server Service Manual Service Manual Part No 819 4359 19 May 2010 Revision A...
Страница 12: ...xii Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 34: ...1 20 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 192: ...3 72 Sun Fire X4500 X4540 Server Service Manual May 2010 FIGURE 3 31 Removing the System Controller...
Страница 196: ...3 76 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 210: ...B 12 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 217: ...Appendix C Status Indicator LEDs C 7 FIGURE C 3 Disk Drive and Fan Trays X4500 Figure Legend 0 Boot drive 1 Boot drive...
Страница 219: ...Appendix C Status Indicator LEDs C 9 FIGURE C 5 Disk Drive and Fan Tray LEDs...
Страница 250: ...E 6 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 256: ...G 4 Sun Fire X4500 X4540 Server Service Manual May 2010...
Страница 264: ...Index 4 Sun Fire X4500 X4540 Server Service Manual May 2010...