![Sun Microsystems StorEdge 3000 Series Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/sun-microsystems/storedge-3000-series/storedge-3000-series_installation-manual_1392457044.webp)
4-10
Sun StorEdge 3000 Family FRU Installation Guide • May 2004
4.5
FC Battery Status and In-Service Date
Procedures
The CLI and SSCS programs offer the following features for FC battery modules:
■
Setting the In-Service Date
■
Monitoring the FC battery status
4.5.1
Viewing Status and Setting the In-Service Date
with the CLI
This command sets the in-service date for battery FRU replacements and displays
the status of the battery modules.
■
For battery FRU replacements, the battery in-service-date must be set manually
with the
show battery-status
command after the battery FRU module is
installed. The
show battery-status
command will prompt you to set the in-
service date to the system clock date. Run this command immediately to ensure
the battery status is accurate when you run the
show battery-status
command in the future.
■
For redundant controllers, status for both batteries is shown. Status values
include: Expired, Warning, or Good. A status of Warning indicates that the battery
will expire within 21 days.
Note –
If the battery type is an early board module, then battery expiration
monitoring is not supported. In this case, a message displays that says, “battery
board type is not supported.”
Содержание StorEdge 3000 Series
Страница 12: ...1 6 Sun StorEdge 3000 Family FRU Installation Guide May 2004 3 Power off both power supply fan modules ...
Страница 34: ...3 8 Sun StorEdge 3000 Family FRU Installation Guide May 2004 ...
Страница 74: ...5 26 Sun StorEdge 3000 Family FRU Installation Guide May 2004 ...
Страница 94: ...6 20 Sun StorEdge 3000 Family FRU Installation Guide May 2004 ...