Chapter 2
Disk Drive, Air Management Sled, and Tabletop Cover FRUs
2-9
4. Disable Periodic Drive Check Time:
From the Main Menu, choose “view and edit Configuration parameters,” then
choose “Drive-side SCSI Parameters.”
Set the “Periodic Drive Check Time” option to Disabled, then confirm Yes. This
procedure is now complete.
2.1.4.4
If the Logical Drive Status is REBUILDING
The rebuilding process refers to the rebuilding of the logical drive in which the data
from a defective disk drive is restored to a global spare.
When you see the REBUILDING status, perform one of the two following
procedures.
■
Wait until the rebuild process is completed, then replace the defective disk drive.
The benefit is that the logical drive is fully restored before you replace the
defective drive. This eliminates the possibility of lost data if the wrong drive is
removed.
or
■
Replace the defective drive and make the new drive a global spare while the
rebuilding process continues.
This procedure installs the new drive and assigns it as a global spare so that
automatic rebuild of a logical drive will occur if a drive fails on any other logical
drive.
Note –
If a disk drive fails on another logical drive prior to the assignment of a new
global spare, you will have to manually rebuild the logical drive.
2.1.4.5
Automatic Rebuild and Automatic Global Spare Assignments
After a Failed Drive is Replaced
You can enable one or both of the following firmware features to expedite the
rebuilding of a logical drive after a defective drive has been replaced:
■
Auto-Assign Global Spare Drive (automatically assigns the next unused drive as a
global spare so that an automatic rebuild can occur when the next failed drive
event occurs)
■
Periodic Auto-Detect Failure Drive Swap Check Time (periodically polls the
drives, detects when a bad drive has been replaced, and automatically begins the
rebuilding logical drive process as soon as the bad drive has been replaced)
Содержание StorEdge 3000 Series
Страница 12: ...1 6 Sun StorEdge 3000 Family FRU Installation Guide May 2004 3 Power off both power supply fan modules ...
Страница 34: ...3 8 Sun StorEdge 3000 Family FRU Installation Guide May 2004 ...
Страница 74: ...5 26 Sun StorEdge 3000 Family FRU Installation Guide May 2004 ...
Страница 94: ...6 20 Sun StorEdge 3000 Family FRU Installation Guide May 2004 ...