Chapter VI Solutions to Failure
6.1 Failure Analysis and its Solutions
Eliminate the failures if there is failure warning. Close the machine and switch off the power if
necessary. The system is forbidden to run under failure.
The operator should record the failure
’
s type if there appears failure, and press
“
Enter
”
button
for confirming the failure message, and then examine the relevant parts as per the failure
’
s type.
Press
“
Reset
”
button for cleaning the warn message after maintenance and re-start up the
system.
Failure Analysis and its Solutions
Failure
Possible
Reasons
Solutions
Machine
Status
The indicator
light of input
power does not
enlighten.
1.
There is open circuit on
main power supply.
2.
The switch of air supply
at the buffer of main
power supply does not
turn on.
There
is
something
wrong
with
the
indicator light.
1.
Check if there is something
wrong with the wiring of
power supply and if the wires
are
connected
with
the
terminals in good condition.
2.
Check if all melt device has
been connected properly.
3.
Turn on the switch of air
supply or replace it with new
ones.
Stop
The soldering
system cannot
run after
turning on the
machine.
1.
The fuse in control panel
may be melted.
2.
The limiter (heat relay)
may flick up.
3.
Automatic breaker may
disconnect.
4.
Stop knob on emergency
may not flick up.
1.
Replace the fuse with new
ones.
2.
Reset the limiter.
3.
Turn on the breaker.
4.
Revolve the stop knob from
left to right.
Stop