SUPERVISOR CONTROLLER™ USER MANUAL
SECTION 4
18
E-Stop
ALL
ALWAYS
Auxiliary E-Stop String
Open
Check auxiliary E-Stop
devices.
E-Stop String
Check wiring.
Low Water Pressure
ALL
Water-
cooled
Cooling Water Pressure
Below 10 psi (0.7bar)
Check for closed valves or
broken pipes.
Oil Change Due, Oil Filter
Change, Separator Change
Due, Air Filter Change, Oil
Analysis Due, Maintenance
Due
ALL
ALWAYS
Maintenance Due
Select Maintenance from
menu to see service due and
part numbers.
Main Motor Overload
ALL
ALWAYS
Main Motor Overload
Reset overload after heater
element cools down.
Make sure compressor is
properly configurated.
Make sure load pressure is
set below limit of compres-
sor.
Check motor starter contacts
for proper operation.
Check line voltage, if low
consult power company.
I/O Mod Com Error, Com Mod
Com Error, Motor Mod Com
Error, VSD Com Error
ALL
ALWAYS
Module Network Error; The
Network that Connects the
Display Module, I/O Mod-
ule and Other Optional
Modules is Not Working
Correctly
Check wiring.
Replace module referred to
in error message, if problem
persists replace display mod-
ule.
Oil Filter Maint., dP2 Oil Filter
High
ALL
ALWAYS
Pressure Across Oil Filter
Above 20 psi (1.4 bar)
While Running
Oil filter clogged, replace oil
filter.
FLOODED
ALWAYS
Low ambient temperature,
sump heater may be
required in ambients below
40°F (4°C).
ALL
ALWAYS
Sensor failure, check sen-
sor, wiring and tubing.
Table 4-1: Troubleshooting Guide—Supervisor Controller
Message
Model
Enable
Probable Cause
Remedy
Содержание SUPERVISOR CONTROLLER
Страница 8: ...NOTES 6...
Страница 15: ...13 NOTES...
Страница 16: ...SUPERVISOR CONTROLLER USER MANUAL SECTION 2 14 Table 2 1 Supervisor Controller Menu Tree...
Страница 18: ...16 NOTES...
Страница 30: ...28 NOTES...
Страница 31: ...Section 5 29 SUPERVISOR CONTROLLER USER MANUAL WIRING DIAGRAMS...
Страница 49: ...SECTION 6 SUPERVISOR CONTROLLER USER MANUAL 47 VSD FILTER DRAWING V200TS FILTER ELEMENT Figure 6 2 V200TS...
Страница 51: ...NOTES...