P1 Sump Pressure Low
FLOODED
ALWAYS
Sump Pressure Low
Check pressure sensor, wir-
ing and tubing.
Machine may have failed to
start.
T1 Interstage HIgh, T2 Dis-
charge High, T3 Oil Temp
HIgh, T4 Intercool High, T5
Discharge High, T1 Dis-
charge High, T2 Dry Side
High, T3 Oil Temp High, T4
Interstage High
ALL
ALWAYS
High Temp. Fault
Ambient above 105°F
(41°C), improve local ventila-
tion.
FLOODED
ALWAYS
Fluid level low, replenish to
proper level.
Thermal valve, check opera-
tion
ALL
ALWAYS
Cooler fins dirty, clean fins
and fan.
Water-
cooled
Low water flow, check for
valve closed, pump off or
broken pipe.
Water-
cooled
High water temperature,
increase flow or lower water
temperature.
Water-
cooled
Cooler plugged, clean tubes
and shell, if plugging per-
sists, use cleaner water.
ALWAYS
Sensor failure, check sensor
and wiring.
Power Interruption
ALL
ALWAYS
Motor Starter(s) Not Work-
ing
Check starter controls and
wiring
No Contatct to Input D8
Check wiring to input.
Intermittent Control Power
Check line voltage and con-
nections.
VSD Emergency Stop
ALL
VSD
E-Stop Button Active
Release button.
Table 4-1: Troubleshooting Guide—Supervisor Controller
Message
Model
Enable
Probable Cause
Remedy
Содержание SUPERVISOR CONTROLLER
Страница 8: ...NOTES 6...
Страница 15: ...13 NOTES...
Страница 16: ...SUPERVISOR CONTROLLER USER MANUAL SECTION 2 14 Table 2 1 Supervisor Controller Menu Tree...
Страница 18: ...16 NOTES...
Страница 30: ...28 NOTES...
Страница 31: ...Section 5 29 SUPERVISOR CONTROLLER USER MANUAL WIRING DIAGRAMS...
Страница 49: ...SECTION 6 SUPERVISOR CONTROLLER USER MANUAL 47 VSD FILTER DRAWING V200TS FILTER ELEMENT Figure 6 2 V200TS...
Страница 51: ...NOTES...