SUPERVISOR CONTROLLER™ USER MANUAL
SECTION 2
10
Restart Time is set to 10 seconds, then the machine
will be enabled to start after 10 seconds.
Wye to delta transition timer
—Also used to control
the closed inlet start valve. Disable by setting to zero
(0), standard for full voltage start. Requires
approximately 4-6 seconds for wye-delta or solid
state starting.
Modulate
—Default state is Yes for normal machine
control. Select No for Load/No Load operation.
Language select
—English, German, Spanish,
Italian and French may be selected for display
language.
Temp Units
—Temperature units may be set to
degrees F or degrees C.
Press Units
—Pressure units may be set to psi, bar,
or kPa.
(VSD packages only)
—Additional adjustments for
VSD operation are shown in
Section 2
.
2.6
MAINTENANCE—
PREVENTIVE
MAINTENANCE
INFORMATION AND TIMERS
The following lines are on the Maintenance display.
Information—The top two lines may be changed to
advise what to do when there is a maintenance
warning. For example a distributor can put in his
name and telephone number.
Ser. No—
Serial number of machine.
Warn at
—When the following drop below this
number, a warning is issued.
Oil Filter hours
—Hours before oil filter change.
PN
—Oil Filter part number.
Separator hours
—Hours before separator change.
Prim.—
Primary separator part number.
Sec.—
Secondary separator part number.
Air Filter hours—
Hours before air filter change.
Prim.—
Primary air filter part number.
Sec.—
Secondary air filter part number.
Oil hours
—Hours before oil change.
PN
—Oil part number.
Oil Anal.—
Hours before oil analysis.
These hours and part numbers can be changed
using the enter and arrow keys.
2.7
FAULT LOG—LOG OF
PREVIOUS FAULTS
The fault log shows the last 16 faults that occurred.
The top line of the display shows the run hours where
the fault occurred, and the second line shows the
fault. The faults can be scrolled through using the up
and down arrow keys. They are ordered by most
recent first. (ie. when the function is entered the most
recent fault is displayed. Pressing the down arrow
displays the previous fault etc).
2.8
SENSOR LOG
Log of sensor readings leading up to a fault.
The sensor log shows the sensor readings leading
up to a fault. The top line shows the last fault. The
following lines show T1, T2, P1 & P2. Each line
represents readings that are 5 seconds apart for one
minute, then one minute apart for 10 minutes. There
is a second set of readings for T3, T4, P3 & P4.
2.9
SEQUENCING—
SEQUENCING &
COMMUNICATION
PARAMETERS
The following parameters can be viewed and edited.
For more details on sequencing see the Supervisor
Sequencing and Protocol Manual.
Sequence By
—Sequencing mode can be set to:
Disabled
—Control does not do any sequencing.
Remote
—Enables Remote Start/Stop, Remote
Load/Unload and Local/Master inputs
Hours
—Uses the Seq Hrs parameter to deter
mine order of sequencing
Number
—Uses the Com Number to determine
order of sequencing
Seq Hrs
—This is an hour counter used when the
‘Sequence By’ parameter is set to ‘Hours’. Each hour
NOTE
Unload pressure MUST be lowered to
rated pressure when using Load/No Load
mode.
Содержание SUPERVISOR CONTROLLER
Страница 8: ...NOTES 6...
Страница 15: ...13 NOTES...
Страница 16: ...SUPERVISOR CONTROLLER USER MANUAL SECTION 2 14 Table 2 1 Supervisor Controller Menu Tree...
Страница 18: ...16 NOTES...
Страница 30: ...28 NOTES...
Страница 31: ...Section 5 29 SUPERVISOR CONTROLLER USER MANUAL WIRING DIAGRAMS...
Страница 49: ...SECTION 6 SUPERVISOR CONTROLLER USER MANUAL 47 VSD FILTER DRAWING V200TS FILTER ELEMENT Figure 6 2 V200TS...
Страница 51: ...NOTES...