MAINTENANCE MANUAL
STORM Century S-LSA
STORM Century S-LSA
STORMAIRCRAFT
FUEL SHUT – OFF VALVE
The two ways shut of valve is controlled by an OPEN / CLOSED switch on the central console, in
front of the throttles.
FUEL PIPES
From wing tanks to the auxiliary tank : Rilsan 8/6 mm
From the auxiliary tank through the firewall rubber fuel pipe inside diameter 7 mm.
Caution:
use only piping agreed for unleaded fuel
FLOAT
If installed It is accessible through the inspection hole on the wing.
To remove you must disassemble the wing (see Chapter 3.2.1)
5.2.1 FITTING REMOVAL AND INSTALLATION
CAUTION
: before you proceed with the removal of: gascolator, electric pump, mechanical
pump and feed cock, the remaining fuel must be drained from the tank.
REMOVAL
Gascolator, electric pump, mechanical pump :
a) close feed cock
b) disconnect fuel pipes
c) disconnect electrical system from electric pump
d) remove locking nuts from firewall and engine
CAUTION
: should a malfunction of the mechanical pump occur, it cannot be repaired. It has to be
replaced.
INSTALLATION
gascolator, electric pump, mechanical pump :
invert removal sequence
Содержание Century S-LSA
Страница 13: ...MAINTENANCE MANUAL STORM Century S LSA STORM Century S LSA STORMAIRCRAFT 1 4 ENGINE SPECIFICATIONS ...
Страница 74: ...MAINTENANCE MANUAL STORM Century S LSA STORM Century S LSA STORMAIRCRAFT Fig 3 24 Fig 3 25 ...
Страница 114: ...MAINTENANCE MANUAL STORM Century S LSA STORM Century S LSA STORMAIRCRAFT CHAPTER 9 ELECTRICAL SYSTEM DIAGRAM Fig 9 1 ...
Страница 129: ...MAINTENANCE MANUAL STORM Century S LSA STORM Century S LSA STORMAIRCRAFT 10 7 3 FIREWALL ELECTRIC PANEL Fig 10 7 ...