ID 442454.02
43
WE KEEP THINGS MOVING
Basic information
2
Operation manual CiA 402 Controller Based
2.3.2
Drive-generated internal feed forward
Use drive-generated internal feed forward if a feed forward should return the
desired results for the entire period of operation once it has been set.
Setting up internal feed forward in DriveControlSuite
•
Set
I25 Velocity feed forward
to a value that is suitable for your application,
e. g. to 80 %.
•
Activate internal feed forward with
I425 = 0: internal - linear v+x
or
2:
internal - linear x
or
4: internal - quadratic x
.
•
The control unit transfers only
A601 Interpolation data record
.
2.3.3
Without feed forward
Select this setting if the overall setting of the drive controller is sufficiently
optimized so that active feed forward would have an adverse affect on overall
control.
Deactivating feed forward in DriveControlSuite
•
Set
I25 Speed feed forward
= 0 %.
•
The control unit transfers only
A601 Interpolation data record
.
Interpolation
d/dt
I25
X
soll cycl
X
soll
V
soll
V = 0
soll
Interpolation
X
soll cycl
X
soll