Referencing method 1
Referencing method 1 is characterized by the following features:
•
Negative limit switch
•
Encoder zero pulse
•
Negative initial movement
Sequence
1. The drive starts in negative direction with ramp
A588
and speed
A587.0
.
2. The drive turns around on the negative limit switch and changes to speed
A587.1
.
3. When the zero pulse is detected, the reference is set.
4. The drive comes to a complete stop with ramp
A588
.
2.2.3.3.2
Referencing method 2
Referencing method 2 is characterized by the following features:
•
Positive limit switch
•
Encoder zero pulse
•
Positive initial movement
Sequence
1. The drive starts in positive direction with ramp
A588
and speed
A587.0
.
2. The drive turns around on the positive limit switch and changes to speed
A587.1
.
3. When the zero pulse is detected, the reference is set.
4. The drive comes to a complete stop with ramp
A588
.
ZP
LS-
LS-
1
LS+
LS+
2
ZP
LS+
LS-