ID 442454.02
14
WE KEEP THINGS MOVING
Basic information
2
Operation manual CiA 402 Controller Based
2.2
Operating modes
Different operation modes are available with the CiA CB application.
For commissioning, emergency mode and for maintenance and repair
work:
•
Jog
Control-independent movement of the drive.
You can also use the following operation modes with CiA CB in accordance
with CANopen device profile CiA 402.
For referencing
:
•
Homing mode
Control-independent referencing of the drive. The drive calculates the
necessary motion profiles independently.
In production mode
:
•
Interpolated position mode
Cyclic position assignment by the control unit. Position-controlled drive.
•
Cyclic synchronous position mode
Cyclic position assignment by the control unit. Position-controlled drive.
•
Cyclic synchronous velocity mode
Cyclic velocity assignment by the control unit. Velocity-controlled drive.
•
Cyclic synchronous torque mode
Cyclic torque/force assignment by the controller. Torque-/force-controlled
drive.
2.2.1
Selection of the active operation mode
You can choose the desired operation mode in parameter
A541 Modes of
operation
. The currently active operation mode is displayed via the parameter
A542 Modes of operation display
.
2.2.2
Jog
You can use Jogging mode to move the drive independently of the control unit,
for example during commissioning, in emergency mode, or for setup and repair
work.