ID 442454.02
12
WE KEEP THINGS MOVING
Basic information
2
Operation manual CiA 402 Controller Based
9
Operation enabled > switch on disable
Enable inactive
OR
command
Disable voltage
OR
safety technology active
10 Switched on > switch on disable
Enable inactive
OR
DC link not charged
OR
command
Quick stop
OR
command
Disable voltage
OR
safety technology active
OR
(IGB motion bus active
AND
IGB state not equal to
3:IGB motion bus
AND
IGB exception mode inactive
AND
local mode inactive)
11
Operation enabled > quick stop
Command
Quick stop
OR
(Enable inactive
AND
Quick stop
signal
with enable off
signal active)
12 Quick stop > switch on disable
Quick stop complete
OR
DC link below 130 V
OR
safety technology active
OR
command
Disable voltage
13 All states > fault response active
Fault detected
14 Fault response active > fault
Fault response complete
15 Fault > switch on disable
Command
Fault reset
(positive edge)
Change of state
Conditions