ID 442454.02
31
WE KEEP THINGS MOVING
Basic information
2
Operation manual CiA 402 Controller Based
2.2.3.3.16
Referencing method -1
Referencing method -1 is characterized by the following features:
•
Torque/force stop
•
Positive initial movement
Sequence
1. The drive starts in positive direction with the ramp set in
A588
and at the
speed set in
A587.0
.
2. If the torque limit set in
I28
is interrupted for at least the time set in
I29
or
more, the reference is set.
3. Reference values are ramped to zero with a value set in
A588
.
2.2.3.3.17
Referencing method -2
Referencing method -2 is characterized by the following features:
•
Torque/force stop
•
Negative initial movement
Sequence
1. The drive starts in negative direction with the ramp set in
A588
and at the
speed set in
A587.0
.
2. If the torque limit set in
I28
is interrupted for at least the time set in
I29
or
more, the reference is set.
3. Reference values are ramped to zero with a value set in
A588
.
1
2