ID 442454.02
35
WE KEEP THINGS MOVING
Basic information
2
Operation manual CiA 402 Controller Based
2.2.4.2
Control commands and status information
To select the "Interpolated position mode" operation mode, set the parameter
A541
to the value 7.
The active operation mode is output in
A542 Modes of operation display
. If
Interpolated position mode is active, the display contains as information 7:
Interpolated position mode.
The following operating-mode-specific bits are assigned in the control word:
The following operating-mode-specific bits are assigned in the status word:
2.2.5
Cyclic synchronous position mode
You can use Cyclic synchronous position mode to implement cyclic position
assignment with a control unit. Position control is performed in the drive.
The control includes a reference position (with a time stamp) and if applicable
a reference velocity that is processed as a feed forward. The application
interpolates the reference values and forwards them to the position controller.
Acceleration, brake or jerk limits are not taken into consideration.
A515 control word
Bit
Designation
Description
4
Operation mode specific
Enable interpolation
(1: Enable interpolation)
A516 status word
Bit
Designation
Description
12
Operation mode specific Interpolated position mode active
(ip active)