To select the "Cyclic synchronous torque mode" operation mode, set the
parameter
A541
to the value 10.
The active operation mode is output in
A542 Modes of operation display
. If
Cyclic synchronous torque mode is active, the display contains as information
10: Cyclic synchronous torque mode
.
No mode-specific control commands need to be entered in control word
A515
Control word
.
The following operating-mode-specific bits are assigned in the status word:
A516 status word
Bit
Designation
Description
12
Operation mode specific Drive follows the reference value