Electrical characteristics
STM32L151x6/8/B, STM32L152x6/8/B
94/129
DocID17659 Rev 10
Table 55. ADC accuracy
(1)(2)
Symbol
Parameter
Test conditions
Min
Typ
Max
(3)
Unit
ET
Total unadjusted error
2.4 V
≤
V
DDA
≤
3.6 V
2.4 V
≤
V
REF+
≤
3.6 V
f
ADC
= 8 MHz, R
AIN
= 50
Ω
T
A
= -40 to 105
°
C
-
2
4
LSB
EO
Offset error
-
1
2
EG
Gain error
-
1.5
3.5
ED
Differential linearity error
-
1
2
EL
Integral linearity error
-
1.7
3
ENOB
Effective number of bits
2.4 V
≤
V
DDA
≤
3.6 V
V
DDA =
V
REF+
f
ADC
= 16 MHz, R
AIN
= 50
Ω
T
A
= -40 to 105
°
C
1 kHz
≤
F
input
≤
100 kHz
9.2
10
-
bits
SINAD
Signal-to-noise and
distortion ratio
57.5
62
-
dB
SNR
Signal-to-noise ratio
57.5
62
-
THD
Total harmonic distortion
-74
-75
-
ET
Total unadjusted error
2.4 V
≤
V
DDA
≤
3.6 V
1.8 V
≤
V
REF+
≤
2.4 V
f
ADC
= 4 MHz, R
AIN
= 50
Ω
T
A
= -40 to 105
°
C
-
4
6.5
LSB
EO
Offset error
-
2
4
EG
Gain error
-
4
6
ED
Differential linearity error
-
1
2
EL
Integral linearity error
-
1.5
3
ET
Total unadjusted error
1.8 V
≤
V
DDA
≤
2.4 V
1.8 V
≤
V
REF+
≤
2.4 V
f
ADC
= 4 MHz, R
AIN
= 50
Ω
T
A
= -40 to 105
°
C
-
2
3
LSB
EO
Offset error
-
1
1.5
EG
Gain error
-
1.5
2
ED
Differential linearity error
-
1
2
EL
Integral linearity error
-
1
1.5
1. ADC DC accuracy values are measured after internal calibration.
2. ADC accuracy vs. negative injection current: Injecting a negative current on any analog input pins should be avoided as this
significantly reduces the accuracy of the conversion being performed on another analog input. It is recommended to add a
Schottky diode (pin to ground) to analog pins which may potentially inject negative currents.
Any positive injection current within the limits specified for I
INJ(PIN)
and
Σ
I
INJ(PIN)
does not affect the ADC
accuracy.
3. Based on characterization, not tested in production.