Electrical characteristics
STM32L151x6/8/B, STM32L152x6/8/B
56/129
DocID17659 Rev 10
Table 17. Current consumption in Run mode, code with data processing running from Flash
Symbol Parameter
Conditions
f
HCLK
Typ
Max
(1)
Unit
55 °C 85 °C 105 °C
I
DD (Run
from
Flash)
Supply
current in
Run mode,
code
executed
from Flash
f
HSE
= f
HCLK
up to 16 MHz,
included
f
HSE
= f
HCLK
/2
above 16 MHz
(PLL ON)
(2)
Range 3,
V
CORE
=1.2 V
VOS[1:0] = 11
1 MHz
270
400
400
400
µA
2 MHz
470
600
600
600
4 MHz
890
1025
1025
1025
Range 2,
V
CORE
=1.5 V
VOS[1:0] = 10
4 MHz
1
1.3
1.3
1.3
mA
8 MHz
2
2.5
2.5
2.5
16 MHz
3.9
5
5
5
Range 1,
V
CORE
=1.8 V
VOS[1:0] = 01
8 MHz
2.16
3
3
3
16 MHz
4.8
5.5
5.5
5.5
32 MHz
9.6
11
11
11
HSI clock source
(16 MHz)
Range 2,
V
CORE
=1.5 V
VOS[1:0] = 10
16 MHz
4
5
5
5
Range 1,
V
CORE
=1.8 V
VOS[1:0] = 01
32 MHz
9.4
11
11
11
MSI clock, 65 kHz
Range 3,
V
CORE
=1.2 V
VOS[1:0] = 11
65 kHz
0.05 0.085
0.09
0.1
MSI clock, 524 kHz
524 kHz 0.15 0.185
0.19
0.2
MSI clock,
4.2 MHz
4.2 MHz
0.9
1
1
1
1. Based on characterization, not tested in production, unless otherwise specified.
2. Oscillator bypassed (HSEBYP = 1 in RCC_CR register).