Sterling AB12130 Скачать руководство пользователя страница 5

Optional R

emote Control

Place of Installation

Install the remote control panel in a dry place and in such away that you can 
easily read the display and access the control buttons. 

The installation location should be accessible easily.

The remote panel can be flush-mounted or top-mounted with or without frame:

Drill a hole for the wires into the back board. Slide the small left and right hand 
covers (A) off the front panel which will expose the screws. Unscrew, remove the 
frame (B) and drill the required holes into the back board. Connect all necessary 
wires to the correct terminals at the back of the unit. Mount the unit using the 
frame (B) and suitably long screws onto the back board.Reattach the covers (A) 
onto the front panel.

Slide the small left and right hand covers (A) off the front panel which will 
expose the screws. Unscrew and remove the frame (B). Use the inside of the 
frame (B) as a template for the required cutout in the back board. Carefully cut 
out the back board and connect all necessary wires to the correct terminals at the 
back of the unit. Mount the unit using the four short screws supplied and reattach 
the covers (A) onto the front panel.en.

Remove the small left and right hand covers (A) off the front panel and make a 
cutout of 134mm x 90mm into the back board. Ideally, the back board should not 
be thicker than 3mm; otherwise the front panel will stand back a little. Using the 
actual Power Management Panel as a template, drill the required holes with 
counterbores into the back board. Connect all necessary wires to the correct 
terminals at the back of the unit. Push the unit from behind into the cutout and fix 
it with the screws provided..

Avoid if possible  laying  the remote control cable next to any 230volts a/c cables 
or next to high current d/c cables. This may cause interference and erroneous data 
transmission. Remember, the remote control cable is purely a data transmission 
working on very low voltages.

We strongly recomend not to shorten this cable. If you cut and reconnect the 
cable this may void the warranty of your unit.

When all cables have been correctly laid and connected, reconnect the batteries 
and the alternator.

The alternator-to-battery charger can be switched on and off manually by 
pressing the on/off key ( assumming the alternato is working. Even when the 
charger has been switched off, it will remain on standby mode. Also, the batteries 
will still be charged, but without the boost on the domestic battery side. 

After the unit has been switched on, the remote control will show the software 
release of the charger and the remote control unit. In case you are experiencing a 
problem with your alternator-to-battery charger, please take a note of these 
numbers before you contact us.

When the engine is restarted, the alternator-to-battery charger will also restart, 
even when the charger has been switched off manually before.

The alarm sound indicating any system faults can be muted using the alarm key.

The background light of the display panel can be switched on and off using the 
light key.

Important: The panel must be installed in a dry place!

Basic Functions

1) Top-Mounting with Frame

2) Top-Mounting without Frame

3) Flush-Mounting

Installation of the Remote Control

1) Switching the charger on and off

2) Alarm Sound

3) Background Light

Connect the supplied remote control cable with the remote control unit. On the 
back of the remote panel is a small opening with a socket behind. Mind the 
correct orientation of the plug when you connect the cable. The small clip on top 
of the plug must be directed upwards. Then, connect the remote control cable 
with the corresponding connector on the alternator-to-battery charger. Again, 
mind the correct orientation of the plug! (clip on top).

A

B

BOX INSTALLATION INSTRUCTIONS
SLIDE PARTS A TO EXPOSE SCREW HOLES
FOR FLUSH MOUNT, REMOVE PART B
FOR SURFACE MOUNT KEEP PART B
AFTER INSTALLATION REPLACE PARTS A

FOR MORE INFORMATION PUSH THE 

BUTTON ON THE 

REMOTE CONTROL. AND THE SCREENS WILL AUTOMATICALLY 
SCROLL THROUGH, 

 

FUNCTION 

TO STOP THE AUTOMATIC SCROLLING AND LOCK ONTO ANY OF THE 
BELOW SCREENS THEN SIMPLY PUSH THE FUNCTION BUTTON AGAIN 
AND THE SCREEN WILL SAY SCROLL OFF AND LOCK ON THE SELECTED SCREEN 

ALL VOLTAGE READINGS BELOW ARE JUST EXAMPLES

SCROLLING ON

 

AFTER YOU PUSH THE
FUNCTION BUTTON

SCREENS (START UP )

STERLING EUROPE
PRO MARINER USA

 

ABOUT 2 SECONDS

SEARCHING
****************

 

COMPANIES INVOLVED 
IN THIS PRODUCT

SEARCHING FOR THE 
COMS SIGNAL ,IF MORE
THAN A FEW SECONDS,
CHECK THE LINK  CABLE
AND CONNECTORS

ABOUT 2 SECONDS

ALTERN > BATTERY
IN 12V - OUT 12V

 

PRODUCT INFORMATION
MODEL TYPE 

ABOUT 2 SECONDS

BATTERY TYPE SET
FLOODED POS 6

 

SHOWING INFORMATION 
ON THE BATTERY TYPE 
SETTING, TO CHANGE 
ADJUST BATTERY TYPE
POT 

ABOUT 2 SECONDS

FAST CHARGE
14.8 VOLTS

 

SHOWING THE CHARGE 
STATE & VOLTS IE 
FAST/ADSORPTION/FLOAT
CHARGE. 

DEFAULT SCREEN  

ABOUT 2 SECONDS

STARTER OUTPUT
13.1 VOLTS

 

REFERS TO THE STARTER
BATTERY VOLTAGE 
TAKEN AT OUR UNITS  
TERMINAL

ABOUT 5 SECONDS

DOMESTIC BATTERY
    NO DATA

 

REFERS TO THE DOMESTIC
BATTERY BANK VOLTAGE
IF THE REMOTE SENSE 
WIRE IS USED ONLY. IF 
NOT USED THEN NO DATA 

ABOUT 5 SECONDS

POWER BOOST
     20%

 

SHOWING BETWEEN
1-100% THIS IS THE 
EFFECTIVE BOOST 
1%= LITTLE WORK
100% = MAX WORK

ABOUT 5 SECONDS

UNIT INTERN TEMP
82 F      28 C

 

UNIT TEMP SHOWN 
IN DEGREE C AND IN
DEGREE F THE UNIT WILL
SWITCH OFF AT 80 DEG C

ABOUT 5 SECONDS

ALTERNATOR TEMP 
  NO SENSE

 

ALTERNATOR TEMP
IF SENSOR FITTED, IF 
SENSOR NOT FITTED THEN 
NO SENSE. 

ABOUT 5 SECONDS

BATTERY TEMP
  NO SENSE

 

BATTERY TEMP
IF SENSOR FITTED, IF
SENSOR NOT FITTED THEN 
NO SENSE. 

ABOUT 5 SECONDS

FLOAT CHARGE
13.4 V

WHAT PART OF THE 
CHARGE CYCLE THE 
UNIT IS CURRENTLY ON 
AND THE VOLTAGE. IE
FAST/ABSORBTION/FLOAT

ABOUT 5 SECONDS

DOMESTIC OUTPUT
    14.7 VOLTS

 

DOMESTIC OUTPUT
VOLTAGE AT OUR STUD

 

ABOUT 5 SECONDS

ALTERNATOR INPUT
    14.0 VOLTS

 

ALTERNATOR INPUT
VOLTAGE TAKEN AT THE
INPUT STUD AT
OUR UNIT

 

ABOUT 5 SECONDS

ADSORPTION TIME
    154 MINS

 

WHEN THE CYCLE IS
ON ADSORPTION 
MODE, THIS IS THE COUNT
DOWN TIMER UNTIL
IT GOES ONTO FLOAT

www.busse-yachtshop.de  |  [email protected]

Содержание AB12130

Страница 1: ...E I D S I G C N I M A N Y D ProDigital RoHS compliant www sterling power com www sterling power usa com Alternator to Battery Chargers and Remote Control STERLING POWER PRODUCTS e1 12 v 80 130 amp 24...

Страница 2: ...d ALTERNATOR INPUT Then simply connect the other studs to the engine battery General Overview and to the domestic battery respectively Make sure that the cables used can carry The Sterling alternator...

Страница 3: ...nt for their batteries Again we would strongly recommend you contact your battery supplier to confirm which charging option they require for their batteries This higher voltage appears to be for AGM b...

Страница 4: ...ank or you have some other charging source on your output battery bank which is overcharging the batteries and our unit thinks it is at fault ie if there was a battery charger or solar cell which was...

Страница 5: ...ults can be muted using the alarm key The background light of the display panel can be switched on and off using the light key Important The panel must be installed in a dry place Basic Functions 1 To...

Страница 6: ...ulator has failed in some way and its going to damage over charge your batteries in this case when the trip is activated the voltage should drop down to within safe limits about 14 volts the unit is t...

Страница 7: ...Fuse GANL A 100 or 200 amp L GAN 1 1 m N 1 X 2 m I 1 X FU D O TP 12 mm SE U UT 290 g fuse fuse fuse 8 8 8 8 1 2 3 MINIMUM SYSTEM WIRING BASIC INSTALLATION Designed in UK Made in Taiwan STERLING POWER...

Страница 8: ...ME FLOATING VOLTAGE Battery type rotary selection switch ROTARY SWITCH FUNCTIONS 6 7 5 8 4 9 3 2 0 1 MAX CHARGING VOLTAGE 1 gel usa 14 0 v 1 10 hrs 13 7 v 2 agm 1 usa 14 35 v 1 8 hrs 13 35 v 3 sealed...

Страница 9: ...n a little to enable the standard alternator regulator to produce its full current you can clearly see that the standard alternator voltage is at position on the voltage curve however the input voltag...

Страница 10: ...er t arbeitet explosiver Gase zu vermeiden stellen Sie sicher dass die Batterien mindestens 4 Stunden vor Beginn der Das Lichtmaschinen Batterie Ladeger t maximiert die Installationsarbeiten nicht gel...

Страница 11: ...rter bzw der Verbraucherbatterie Versichern Sie sich dass Lichtmaschinen Batterie Ladeger t eine Trenndiode enth lt liegt die verwendeten Kabel f r den maximalen Strom der am B Ausgang der Lichtmaschi...

Страница 12: ...ie diese wenn POS 6 OFFENE BLEI S URE Einstellung f r Blei S ure erforderlich Falls die neue Sicherung anschlie end erneut Batterien deren Verschlusskappen zum Nachf llen von Wasser durchbrennt setzen...

Страница 13: ...hritten Das Ger t ist im Standby bis die Temperatur einen Normalwert erreicht hat 2x blinkend pause Einer der 3 internen Temperatursensoren ist defekt Das Ger t muss zur Reparatur in eine Sterling Ser...

Страница 14: ...e Kante zu bekommen Das Panel sollte eine maximale St rke von 3mm aufweisen Bei Ort der Inbetriebnahme mehr als 3mm steht die Fernbedienung etwas zur ck was vom Erscheinungsbild her nicht optimal ist...

Страница 15: ...tionen dr cken Sie bitte die Select Taste f r jeweils min 1 Sek M chten Sie dass die Anzeige automatisch wechselt dr cken Sie bitte die Function Taste Nun wechselt die Anzeige automatisch alle 5 Sek Z...

Страница 16: ...e die Temperatur der Batterie umgehend Das Ger t ist abgeschaltet Die Lichtmaschinentemperatur ist zu hoch Das Ger t ist im Standby Modus und wartet auf ein Abk hlen der Lima Verbessern Sie die K hlun...

Страница 17: ...TING VOLTAGE Batterie Typ Einstellungen ROTARY SWITCH FUNCTIONS 6 7 5 8 4 9 3 2 0 1 MAX CHARGING VOLTAGE 1 gel usa 14 0 v 1 10 hrs 13 7 v 2 agm 1 usa 14 35 v 1 8 hrs 13 35 v 3 sealed lead acid 14 4 v...

Страница 18: ...oduct to the company Sterling Power Products Ltd will ship the repaired or replaced product back to the customer This warranty is in lieu of all others expressed or implied Vordringliches Ziel unseres...

Страница 19: ...alternateur Sterling est un appareil lectronique compl tement ALTERNATOR INPUT Ensuite connecter les autres bornes la batterie de automatique qui permet de recharger deux batteries depuis un ou plusi...

Страница 20: ...nc beaucoup de combinaisons et ceci ne nous permet pas de fournir une liste exhaustive des fusibles recommand s L installateur choisira le fusible adapt Voici les r gles respecter quant vous choisisse...

Страница 21: ...rtit que la tension batterie est haute la phase de boost est arr t e Cela signifie que le chargeur d alternateur a un probl me et qu il tait en train de surcharger les batteries ou que vous avez une a...

Страница 22: ...que tout probl me qui survient sur l appareil L alarme sonore peut tre d sactiv e en appuyant sur la touche alarme La lumi re de fond peut tre activ e d sactiv e en utilisant le bouton light Important...

Страница 23: ...t Cela arrive g n ralement lorsque le r gulateur de l alternateur est d fectueux et envoie une tension comme ci dessus ceci peut aussi tre d un probl me sur le chargeur d alternateur dans un te doit r...

Страница 24: ...S Advanced Intelligent digital 0 0 volt drop alternator distribution system STERLING POWER PRODUCTS www sterling power com technology 4 U D R L A A B IT G L E I D D E C I S M I A G N N Y D ProDigital...

Страница 25: ...ING VOLTAGE Bouton s lectif du type de batterie Type de batterie 6 7 5 8 4 9 3 2 0 1 Tension de charge 1 gel usa 14 0 v 1 10 hrs 13 7 v 2 agm 1 usa 14 35 v 1 8 hrs 13 35 v 3 sealed lead acid 14 4 v 1...

Страница 26: ...r le d marrage du moteur standard de l alternateur est celle de la position le chargeur d alternateur fait en sorte de r duire cette tension la tension ceci fait que l alternateur produit au maximum d...

Страница 27: ...ERLING POWER PRODUCTS technology 4 U A D L R IT I A G BL D E C I M D A E S N I G Y N D ProDigital remote control Calcium Calcium B15 1 F13 6 Open Lead Acid B14 8 F13 3 AGM US spec B14 6 F13 7 Gel Eur...

Отзывы: