Specifications – 320 Series:
MODEL
SC320-DWS12 SC320-DWS22
SCM320-
DWS12
SCM320-
DWS22
Flow R
ate
1
VIQUA Standard
30 mJ/cm
2
49.2 lpm
(13 gpm)
(3.0 m
3
/hr)
49.2 lpm
(13 gpm)
(3.0 m
3
/hr)
49.2 lpm
(13 gpm)
(3.0 m
3
/hr)
49.2 lpm
(13 gpm)
(3.0 m
3
/hr)
NSF/EPA
40mJ/cm
2
37.8 lpm
(10 gpm)
(2.3 m
3
/hr)
37.8 lpm
(10 gpm)
(2.3 m
3
/hr)
37.8 lpm
(10 gpm)
(2.3 m
3
/hr)
37.8 lpm
(10 gpm)
(2.3 m
3
/hr)
Overall Dimensions
(width x Depth x Height)
62 cm x 20.3 cm x 69.3 cm
(24.4“ x 8“ x 27.3“)
Inlet/Outlet Port Size
1“ FNPT/
Combo 3/4“ FNPT & 1“ MNPT
Shipping Weight
17.7 kg
(39 lbs)
20 kg
(44 lbs)
17.7 kg
(39 lbs)
20 kg
(44 lbs)
Electrical
Voltage
100-240V/
50-60Hz
100-240V/
50-60Hz
100-240V/
50-60Hz
100-240V/
50-60Hz
Power
Consumption
42 W
42 W
42 W
42 W
Lamp Watts
34 W
34 W
34 W
34 W
Maximum Operating
Pressure
8.62 bar
(125 psi)
8.62 bar
(125 psi)
8.62 bar
(125 psi)
8.62 bar
(125 psi)
Ambient Water
Temperature
2-40˚C
(36-104˚F)
2-40˚C
(36-104˚F)
2-40˚C
(36-104˚F)
2-40˚C
(36-104˚F)
Lamp Type
Sterilume™-HO (high-output)
Visual “Power-On”
Yes
Yes
Yes
Yes
Audible Lamp Failure
Yes
Yes
Yes
Yes
Lamp Replacement
Reminder
Yes
Yes
Yes
Yes
Visual Lamp Life
Remaining
Yes
Yes
Yes
Yes
Total Running Time
Yes
Yes
Yes
Yes
254nm UV Monitor
No
No
Yes
Yes
Solenoid Output
(solenoid not incl.)
No
No
Yes
Yes
4-20 mA Output
N/A
N/A
Yes (optional
260134)
Yes (optional
260134)
Chamber Material
304 SS
304 SS
304 SS
304 SS
Filter Housing
one 10“ and
one 20“
high flow
two 20“
high flow
one 10“ and
one 20“
high flow
two 20“
high flow
1.
Flow rates stated @ 95% UVT EOL (flow rates based on UV system only, actual DWS
system flow rates will vary and will be limited by the installed cartridges)
18
Spécifications de 320 séries :
MODÈLE
SC320-DWS1
2
SC320-DWS22
SCM320-
DWS1
2
SCM320-
DWS22
Débit
1
Standard
VIQUA 30 MJ/cm
2
49,2 lpm
(13 gpm)
(3,0 m
3
/hr)
49,2 lpm
(13 gpm)
(3,0 m
3
/hr)
49,2 lpm
(13 gpm)
(3,0 m
3
/hr)
49,2 lpm
(13 gpm)
(3,0 m
3
/hr)
NSF/EPA
40 MJ/cm
2
37 ,8 lpm
(10 gpm)
(2,3 m
3
/hr)
37 ,8 lpm
(10 gpm)
(2,3 m
3
/hr)
37 ,8 lpm
(10 gpm)
(2,3 m
3
/hr)
37 ,8 lpm
(10 gpm)
(2,3 m
3
/hr)
Dimensions hors-tout
(largeur x profondeur x
longueur)
62 cm x 20,3 cm x 69,3 cm
(24,4 po x 8 po x 27 ,3 po)
Dimension des orifices
d’entrée / de sortie
1 po FNPT/
Combo 3/4 po FNPT & 1 po MNPT
Poids à l’expédition
17,7 k
g
(39 lb)
20 kg
(44 lb)
17,7 k
g
(39 lb)
20 kg
(44 lb)
Électricité
Tension
100-240 V/
50-60 Hz
100-240 V/
50-60 Hz
100-240 V/
50-60 Hz
100-240 V/
50-60 Hz
Consommation
42 W
42 W
42 W
42 W
Wat
ts de la lampe
34 W
34 W
34 W
34 W
Pression maximale de
service
8,62 bar
(125 psi)
8,62 bar
(125 psi)
8,62 bar
(125 psi)
8,62 bar
(125 psi)
Température ambiante
de l’eau
2-40 ˚C
(36-104 ˚F)
2-40 ˚C
(36-104 ˚F)
2-40 ˚C
(36-104 ˚F)
2-40 ˚C
(36-104 ˚F)
Type de lampe
Sterilume™ – HO (high output) à flux éle
vé
Affic
hage – mise sous
tension
Oui
Oui
Oui
Oui
Alarme sonore de dé-
faillance
Oui
Oui
Oui
Oui
Aver
tisseur –
remplacement de la lampe
Oui
Oui
Oui
Oui
Affic
hage –
durée d’opération rési-
duelle de la lampe
Oui
Oui
Oui
Oui
Durée totale de
fonctionnement
Oui
Oui
Oui
Oui
Moniteur UV 254 nm
Non
Non
Oui
Oui
Sor
tie d’alimentation pour
électrovanne
Non
Non
Oui
Oui
Sor
tie 4-20 mA
N/A
N/A
Oui (en
option 260134)
Oui (en
option 260134)
Matériaux de la chambre
304 SS
304 SS
304 SS
304 SS
Boîtier du filtre
10 po et 20 po
à débit élevé
2 de 20 po à
débit élevé
10 po et 20 po
à débit élevé
2 de 20 po à
débit élevé
1.
Les débits sont en fonction d’un UVT de 95 % à la fin de la durée d’opération de la
ampe (EOL). (Les débits sont établis uniquement pour l’unité UV
. Les débits du sys
-
tème Cobalt-DWS vont varier et seront limités selon les car
touches utilités.)
18
Содержание SC200-DWS11
Страница 2: ......