14
Technical data
14.1
Inverter
StecaGrid 8000+ 3ph
StecaGrid 10 000+ 3ph
DC input side (PV generator connection)
Number of DC inputs
4
Maximum start voltage
845 V
Maximum input voltage
845 V
Minimum input voltage
350 V
Startup input voltage
350 V
Rated input voltage
600 V
Minimum input voltage for rated
output
350 V
MPP voltage
350 V … 700 V
Maximum input current
32 A
Rated input current
14 A
17.3 A
Maximum input power at maximum
active output power
9,250 W
10,800 W
Rated input power (cos
φ
= 1)
8,400 W
10,400 W
Recommended maximum PV output
10,500 Wp
12,500 Wp
Derating / power limiting
Occurs automatically when:
•
input power > max. recommended PV power
•
cooling is inadequate
•
input current > 32 A
•
grid current > 16 A
•
internal or external power reduction (derating)
•
grid frequency too high (according to country setting)
•
limiting signal received via an external interface
AC output side (mains grid connection)
Output voltage
320 V … 480 V (depending on the country settings)
Rated output voltage
400 V
Maximum output current
16 A
Rated output current
11.6 A
14.3 A
Maximum active power (cos
φ
= 1)
8,800 W
1) 3)
10,300 W
2) 3)
Maximum active power (cos
φ
= 0.95)
8,800 W
3)
9,800 W
3)
Maximum active power (cos
φ
= 0.90)
8,800 W
3)
9,300 W
3)
Maximum apparent power (cos
φ
= 0.95)
9,260 VA
4)
10,300 VA
4)
Maximum apparent power (cos
φ
= 0.90)
9,780 VA
4)
10,300 VA
4)
Rated output
8,000 W
3)
9,900 W
3)
Rated frequency
50 Hz
Grid type
L
1
/ L
2
/ L
3
/ N / PE
Grid frequency
47.5 Hz ... 52 Hz (depending on the country settings)
Power losses in nighttime operation
< 2.5 W
Feeding phases
three-phase
Distortion factor (cos
φ
= 1)
< 4% (max. output)
Power factor cos
φ
0.90 capacitive ... 0.90 inductive
Characterisation of the operating behaviour
Maximum efficiency
96.3%
European efficiency
95.2%
95.4%
MPP efficiency
> 99%
Efficiency values (at 5%, 10%, 20%,
25%, 30%, 50%, 75%, 100% of the
rated power) at rated voltage
83.6%, 92.4%, 95.1%,
95.6%, 95.8%, 96.3%,
95.7%, 95.1%
87.5%, 93.8%, 95.6%,
95.8%, 96%, 96.3%, 95.8%,
95.1%
Efficiency values (at 5%, 10%, 20%,
25%, 30%, 50%, 75%, 100% of the
rated power) at minimum MPP voltage
84.4%, 91.8%, 94.5%, 95%,
95.1%, 95.6%, 94.7%, 94.3%
88.3%, 93.2%, 95%, 95.2%,
95.3%, 95.6%, 94.8%, 94.3%
76
744.378 | 12.13
EN