Event messages
Event message
Description
Type
Grid
frequency
too
low
The grid frequency at the inverter is less than the minimum permissible
value. Due to legal requirements, the inverter switches automatically off
while the error state is present.
Contact your installer if this error occurs frequently.
Grid
frequency
too
high
The grid frequency at the inverter is greater than the maximum permis-
sible value. Due to legal requirements, the inverter switches automatically
off while the error state is present.
Contact your installer if this error occurs frequently.
Grid
freq
.
too
high
for
reac-
tivation
After switching off, the inverter cannot resume feeding because the grid
frequency exceeds the legally prescribed switch-on value.
Contact your installer if this error occurs frequently.
Grid
voltage
too
low
The grid voltage at the inverter is less than the minimum permissible
value. Due to legal requirements, the inverter switches automatically off
while the error state is present.
Contact your installer if this error occurs frequently.
Grid
voltage
too
high
The grid voltage at the inverter is greater than the maximum permissible
value. Due to legal requirements, the inverter switches automatically off
while the error state is present.
Contact your installer if this error occurs frequently.
Grid
voltage
Ø
too
high
The output voltage averaged over the legally prescribed period of time
lies outside the permissible tolerance range. The inverter switches auto-
matically off while the error state is present.
Contact your installer if this error occurs frequently.
Grid
current
DC
Offset
too
high
The DC current portion fed into the grid by the inverter exceeds the maxi-
mum permissible value. The inverter switches off due to legally prescribed
requirements and waits for a prescribed time before switching on again.
If the fault remains present, the inverter switches off again.
Contact your installer.
Resid
.
curr
.
too
high
The residual current exceeds the permissible value. Due to legal require-
ments, the inverter switches automatically off while the error state is
present.
Contact your installer.
Isolation
er-
ror
The isolation resistance between the positive or negative input and earth
is less than the permissible value. For safety reasons the inverter must not
feed into the grid.
Contact your installer.
Fan
faulty
At least one of the internal fans of the inverter is faulty. In certain situa-
tions the inverter will feed less power into the grid (derating).
Contact your installer.
Device
has
overheated
Despite power reduction, the maximum permissible internal temperature
has been exceeded. The inverter feeds no power into the grid until the
maximum permissible temperature is no longer exceeded.
1. Check that the installation conditions are satisfied.
2. Check that the cooling fins and ventilation grill are free from soiling;
see Section 12, p. 75.
3. Contact your installer if this message occurs frequently.
PV
voltage
too
high
The input voltage at the inverter is greater than the maximum permissible
value.
Switch off the main DC switch at the inverter and contact your in-
staller.
Grid
islanding
has
been
de-
tected
There is no grid voltage present (inverter running independently). For
safety reasons, the inverter must not feed into the grid.
Contact your installer if this error occurs frequently.
Time/date
lost
The inverter has lost the time settings because it was disconnected from
the grid for too long. Yields cannot be stored and event messages will
have the wrong date.
Correct the time under
Settings
/
Time/Date
.
74
744.378 | 12.13
EN
Содержание StecaGrid 10 000+ 3ph
Страница 42: ...121 744 378 12 13 Appendix Appendix Zertifikate Certificates Certificats...
Страница 43: ...122 744 378 12 13 Appendix...
Страница 44: ...123 744 378 12 13 Appendix Montage Installation Montage AC Stecker AC plug connecteur AC...
Страница 45: ...124 744 378 12 13 Appendix...
Страница 47: ...744378...